CANCELING THE MELT-CYCLE
Do not cancel the melt-cycle mode if using solid shortening!
The melt-cycle is designed to prevent scorching shortening and overheating the frypot or elements
while gradually melting blocks of shortening. The computer automatically starts the fryer in the
melt-cycle mode and displays
melt-cycle mode until the temperature in the frypot reaches 180°F (82°C) or the melt-cycle is
canceled by the operator
feature.
To cancel the melt cycle on a full pot, press the "R" button. To cancel on a split pot, press the "L"
button for the left side pot and the "R" button for the right side.
decimal point between digits 1 and 2 will illuminate indicating the unit is heating.
USING THE BOIL-OUT FEATURE
Before using this feature, ensure the frypot is filled with a mixture of cold water and
1. To program the fryer for boil-out, press the Program Mode
left display.
NOTE: For split-pot fryers, use the left ON/OFF switch for the left frypot and the right
ON/OFF switch for the right frypot. Both frypots cannot be boiled out simultaneously.
2. Press product buttons 1, 6, 5 and 3 in that order. boil will appear in the right display. The
temperature is automatically set for 195ºF (91ºC). The fryer will attain this temperature and
remain there until the ON/OFF
boilover occurs, turn off the fryer immediately, allow it to cool, then re-enter the boil-out mode
to continue the process.
FRYER RECOVERY TIME CHECK FEATURE
The recovery check is a measurement of the elapsed time required for the fryer to raise the
temperature of the cooking oil from 250°F to 300°F (121°C to 149°C). The computer automatically
checks the recovery time each time the frypot temperature drops below the low-end benchmark of
250°F (121ºC).
To check the recovery time, press the Program Mode Switch
display. Press product buttons 1, 6, 5 and 2 in that order. The recovery time will appear in both
displays for 5 seconds. Although many factors, including the size of the frypot and amount and
temperature of the product placed in the frypot, affect the recovery time, the recovery time should be
DANGER
during the melt-cycle operation. The computer remains in the
If you are not using solid shortening, you may cancel the melt-cycle
.
CAUTION
detergent.
Switch is pressed, which cancels the boil-out mode. If
1 - 6
will be replaced by
Switch.
will appear in the
.
will appear in the left