Setting The Default Load; Setting In/Out Terminals - Sylvania SY20C6144-A Owner's Manual

14” combo; 20” combo
Table of Contents

Advertisement

Other Functions

Setting the Default Load

1
Press the MENU button, the initial MENU is displayed.
2
Press the SHIFT
"Default Load".
3
Press the SET +/- button to set "YES" for the
functions described below.
• The default load function is to Loading for INITIAL data.
- [NO] : Disable INITIAL data loading.
- [YES] : Enable INITIAL data loading.
Checking Usage Duration
1
Press the MENU button, the initial MENU is displayed.
Press the SHIFT
"VCR Mode Set".
2
Press the SHIFT
• The Running Time data
is displayed.
cannot be reset even
though the reset button is
3
Press the SHIFT
pressed. If the RESET
"Running Time".
button is pressed, all data
can be reset except the
running time data.
Drum Running Time : The video heads usage duration.
4
Press the MENU button until the normal screen is
displayed.
38
button until
mark is located in
MENU
Monitor Mode Set
VCR Mode Set
Terminal Output Set
Buzzer Set
YES
Alarm Time
Power Loss Time
√ Default Load
NO
shift:
sel:√
end:MENU
button until
mark is located in
button, the VCR MODE SET menu
button until
mark is located in
VCR MODE SET
Tape Search Select
REC Display Set
REC Set
√ Running Time
00000H
shift:
sel:√
end:MENU

Setting In/Out terminals

1
Press the MENU button, the initial MENU is displayed.
MENU
Monitor Mode Set
VCR Mode Set
√ Terminal Output Set
Buzzer Set
Alarm Time
Power Loss Time
Default Load
shift:
sel:√
end:MENU
2
Press the SHIFT
"Terminal Output Set".
3
Press the SHIFT
menu is displayed.
- ALARM OUT
This terminal is to connect PIR sensors, door contacts or
any type of motion detector.
1) "N/C" (Normally CLOSED Switch Circuit)
If the input becomes DC 5V for 500 msec or more, the
VCR starts alarm recording.
500msec
500msec
2) "N/O" (Normally OPEN Switch Circuit)
If the input becomes 0V for 500 msec or more, the
VCR starts alarm recording.
- TAPE END OUT
1) "High"
During recording, when the end of the tape is
reached, the output becomes DC 5V.
- WARNING OUT
1) "High"
If the Power LED on the front panel continues to flash,
the output becomes DC 5V. If the POWER button is
pressed, the emergency mode is released, then the
output becomes 0V.
Other Functions
TERMINAL OUTPUT SET
√ Alarm Out
High
Tape End Out
High
Warning Out
High
YES
NO
shift:
sel:√
end:MENU
button until
mark is located in
button, the TERMINAL OUTPUT SET
39

Advertisement

Table of Contents
loading

Table of Contents