OBDiag Configuration Variable Settings

The following table provides information about OpenBoot PROM configuration
variables that affect the operation of OBDiag. Use the printenvs command to show
current values and the setenv command to set or change a value.
Variable
Setting
diag-level
off
min
max
128
Sun Enterprise 220R Server Owner's Guide • October 1999
Description
No tests are run at power up
Performs minimal testing of core functionality
Runs exhaustive tests for all functions except
external loopbacks. External loopback tests are
run only if diag-targets is set to loopback,
loopback3, device&loopback, or
device&loopback,3
Default
min