Technical Specifications For The 3222 Submerged Probe - Teledyne 4220 Installation And Operation Manual

Submerged probe flow meter
Table of Contents

Advertisement

Table 1-2 Technical Specifications for the 4220 Flow Meter (Continued)
Memory Partitions
Data Storage
Baud Rates
Storage
Level Data
Flow Rate Calculations
Table 1-3 Technical Specifications for the 3222 Submerged Probe
Dimensions
Weight
Body Material
Cable Length
Operating Temperature
Storage Temperature
Maximum Distances
(between flow meter and level sen-
sor)
Measurement Range
Maximum Level
Measurement Accuracy
Flowlink Data Storage and Retrieval System
Maximum of 6 user-defined memory partitions for level or event stor-
age.
Rate of data storage user-selected in 1, 2, 5, 10, 15, 30, 60, or 120
minute intervals.
Serial connection - 300, 1200, 2400, 4800, or 9600 baud.
Serial connection with the optional internal modem - 2400 baud.
80,000 bytes, apportioned per reading as follows: flow = 4 bytes,
level = 2 bytes, sample = 4 bytes, pH or D. O. = 1 byte)
Level readings are stored as a 16-bit number representing .1mm
(0.0394 inch); effective range is 0–65279 meters.
Flow Conversion
The flow meter creates a table of level-versus-flow rate from program
selections; this table divides the level span into 256 equally-spaced
level increments. Each level increment corresponds to a specific flow
rate. During data collection, if the measured level falls between two
table values, the flow meter will perform a linear interpolation to calcu-
late the flow rate value.
Physical Specifications
7
1
" diameter × 9
" long (2.2 × 24.1 cm).
8
2
3 lb, (including amplifier box and cable) (1.4 kg).
CPVC (chlorinated polyvinyl chloride) housing, stainless steel.
25 ft. (7.6 m).
32° to 160°F (0° to 71°C).
–40° to 160°F (–40° to 71°C).
75 feet (22.7 m) with optional extension cables.
1,000 feet (305 m) with optional Quick-Disconnect Box.
Level Measurement Specifications
0.1 to 10.0 ft. (0.03 to 3.05 meters).
20.0 ft. (6.1 m).
Standard Sensor:
0.033 to 5.0 ft: ±0.008 ft/ft (0.01 to 1.52 m: ±0.008 m/m)
>5.0 ft: ±0.012 ft/ft (>1.52 m: ±0.012 m/m)
@ 77° F (25° C). Includes non-linearity, repeatability, and hysteresis, but does not
include temperature coefficient.
Specifications include nonlinearity, repeatability, and hysteresis, but do not
include a temperature coefficient.