Notes on total flow value display
Note 1: The total flow value and the total difference flow value are displayed to the least
significant digit of the set count rate.
Example:
Total flow / total difference flow display becomes
increases in increments of 0.0001 m
If the value reaches
next count.
In the end, the display becomes
When the set count rate is 10 m
The display becomes
10 m
Note 2: In the case of total difference flow display, if the forward direction total flow value or
reverse direction total flow value exceeds 9,999,999, only the total value that exceeded
9,999,999 will be reset to 0 and the count continues.
Example:
maximum value
Forward direction:1000
Reverse direction:− 100
Flow difference:
* In an example shown above, if the forward direction flow value is reset to zero
after reaching 99999999, flow difference indication changes from 99999899 to
−100 and the count continues.
(5) Percent display
- 1 0 0 . 0
(6) Custom unit display
-
1 0 . 0 T E S T 1 2 3
When the set count rate is 0.0001 m
3
.
When the forward direction value returns to zero after it reaches the
Forward
Reverse direction:
900
Flow difference: 99999999
%
- 42 -
3
3
.
, the display changes to
.
3
and the value increases in increments of
direction:
99999999
− 100
Displayed to one decimal place (0.1%).
Up to 125.0% is displayed.
Flow direction: Forward direction " " (blank)
Reverse direction " − "
Unit can be displayed up to 7 digits.
Value is indicated in 8 digits including a decimal point.
(Up to 9999999)
3
4 significant digits: m
/min value multiplied by the set
coefficient
Flow direction: Forward direction " " (blank)
Reverse direction " − "
6F8A0917
and the value
at the
Forward direction:
Reverse direction:− 100
Flow difference: − 100
0