Alignment

The wind vane does not need any alignment after mounting
when a Vaisala cross arm is used. The mounting screws are
located at the bottom of the sensor so that you can mount
the sensor in one position only to the flange.

Verification

If your sensor is connected to the data collection system and
powered up, check that the directional readings are correct
by holding the vane in a few fixed angles and verifying data.
The connector for the WAV151 Wind Vane is shown in
Figure 5 below. The heating element in the shaft tunnel is
connected between pins J and K. You can supply the heating
element with 20 VDC or VAC.
The recommended cable connector for the sensor is
SOURIAU MS3116F12-10P.
Figure 5
WAV151 Connector