Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1 Manual page 62

Midea air conditioner service manual
Table of Contents

Advertisement

8.11
Forced cooling function
8.11.1 Select forced cooling function with the forced cooling button or the switch.
8.11.2 The compressor is unconditionally turned on, after 30 minutes cooling operation whose
fan mode is set as low, the A/C operates under the DRY mode with a set temp. of 24¡ æ .
8.11.3 All protections of remote control cooling are available under forced cooling operation.
8.12
Forced Auto function
Select forced auto function with the forced auto button or the switch.
In forced auto status the A/C operates under remote control mode with a set temp. of
24¡ æ .
8.13
Timer Function Requirement
The maximum length of timer is 24 hours and the minimum resolving power is 15
minutes.
8.14
Economic Running
8.14.1 The economic running function is available under cooling, heating or auto mode.
8.14.2 Cooling:
The set temperature rise 1¡ æ
maintain as a constant and the air circulation is kept at low speed.
8.14.3 Heating:
The set temperature decrease 1¡ æ
maintain as a constant and the air circulation is kept at low speed (Cold air proof
function takes precedence over all).
8.14.4 Auto:
The economic running function operates in accordance with the selected running mode
by the auto mode.
8.15
Outdoor fan motor
T4: Outdoor temp.
Cooling mode
Heating mode
per hour. Two hours later, the set temperature will
per hour. Two hours later, the set temperature will
T4
Outdoor fan motor
T4>27¡ æ
High speed
T4<25¡ æ
Low speed
T4>13¡ æ
Low speed
T4<11¡ æ
High speed
226