Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1 Manual page 179

Midea air conditioner service manual
Table of Contents

Advertisement

off, the buzzer buzzes lasts for 1 seconds, then A/C turns to be closedown status.
8.8.2.
Forced Auto
8.8.2.1 Remote control signal can be received in forced auto mode. When receiving the signals, the
forced auto mode will be canceled and the A/C changes to remote control status and performs
operation as the signals indicates.
8.8.2.2 The system performs control according to the remote control auto mode with a set temperature of
24°c.
8.9
Timer
24 hours timer on or off.
8.10
Protecting Function
8.10.1
Compress with a delay of 3 minutes.
8.10.2
Sensor open and break protection
8.10.3
EEPROM error protection.
8.10.4
Current protection function.
Current up
Current
down
8.11
Auto restart Function
In case of a sudden power failure, this function automatically sets the unit to previous settings
before the power failure when power returns.
Condition
Indoor fan
I< I
RESTORE
I
<I< I
RESTORE
FAN
I
<I<I
FAN
5MIN
I
<I< I
5MIN
3SEC
I
<I< I
5MIN
3SEC
I
<I<I
FAN
5MIN
I
<I< I
RESTORE
FAN
I< I
RESTORE
Compressor
On
On
On
On
Low speed
On
Off
Off
Off
Off
On
On
Low speed
On
On
On
113
Outdoor fan
Remark
On
Off
Heating mode
On
Cooling mode
Off
After 5 Minutes
Off
After 3 Seconds
Off
After 3 Seconds
Off
After 5 Minutes
Off
Heating mode
On
Cooling mode
On