Service manual 2. Function Indoor unit Operation ON/OFF by remote controller Sensing by room temperature Room temperature sensor. Pipe temperature sensor. Room temperature control Maintain the room temperature in accordance with the setting temperature. Starting temperature control Indoor fan is delayed for 5 sec at the starting. Time Delay Safety control Restarting is for approx.
Service manual Outdoor unit Power relay control The unit has 3 mins delay between continuously ON/OFF operations. Low ambient kit The unit can operate in cooling mode at low ambient temperature conditions. Low noise air flow system Bird tail propeller fan makes the outdoor unit run more quietly. Hydrophilic aluminum fin The hydrophilic fin can improve the heating efficiency at operation mode.
Page 7
Service manual 3. Dimension 3.1 Indoor unit Dimension Mode 1080 1080 1250 - 5 -...
Service manual 4. Specification Model MSG-24CR MSG-24HR Power supply Ph-V-Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz Capacity Btu/h 24000 24000 Input 2750 2750 Cooling Rated current 12.5 12.5 Btu/w.h 8.7, 2.6 8.7, 2.6 Capacity Btu/h 27000 ----- Input ----- 2750 Heating Rated current 12.5...
Page 10
Service manual Model MSG-30CR MSG-30HR Power supply Ph-V-Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz Capacity Btu/h 28000 28000 Input 3200 3200 Cooling Rated current Btu/w.h Capacity Btu/h ----- 30000 Input ----- 3100 Heating Rated current 14.5 ----- ----- Max. current Starting current Model ZR34KH-PFJ-522 ZR34KH-PFJ-522...
Page 11
Service manual Model MSG-36CR MSG-36HR Power supply Ph-V-Hz 1, 220-240V~, 50Hz 1, 220-240V~, 50Hz Capacity Btu/h 35000 35000 Input 4120 4120 Cooling Rated current 18.6 18.6 Btu/w.h Capacity Btu/h 38000 ----- Input 4100 ----- Heating Rated current 18.5 ----- ----- Max.
Page 12
Service manual Model MSG-30CR MSG-30HR Power supply Ph-V-Hz 3Ph,380-420V,50Hz 3Ph,380-420V,50Hz Capacity Btu/h 28000 28000 Input 3000 3000 Cooling Rated current Btu/w.h Capacity Btu/h 32000 ----- Input ----- 3000 Heating Rated current ----- ----- 10.7 Max. current Starting current Model ZR34KH-TFD-522 ZR34KH-TFD-522 Type Scroll...
Page 13
Service manual Model MSG-36CR MSG-36HR Power supply Ph-V-Hz 3, 380-420V~, 50Hz 3, 380-420V~, 50Hz Capacity Btu/h 35000 35000 Input 4120 4120 Cooling Rated current Btu/w.h Capacity Btu/h ----- 38000 Input ----- 4100 Heating Rated current ----- ----- Max. current Starting current Model ZR34KH-TFD-522 ZR34KH-TFD-522...
Service manual 8. Installation details Wrench torque sheet for installation Outside diameter Torque inch Kg.m φ6.35 φ9.52 φ12.7 φ15.88 φ19.05 Connecting the cables The power cord of connect should be selected according to the following specifications sheet. Grade Unit Pipe length and the elevation Standard Max.
Service manual Air purging of the piping and indoor unit Required tools: Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak detector. Note: The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration piping, it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction of unit.
Service manual Pumping down (Re-installation) Procedure 1. Confirm that both the 2-way and 3-way valves are set to the opened position. § Remove the valve stem caps and confirm that the valve stems are in the opened position. § Be sure to use a hexagonal wrench to operate the valve stems. 2.
Service manual Re-air purging (Re-installation) Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the closed position. 2. Connect the charge set and a charging cylinder to the service port of the 3-way valve. § Leave the valve on the charging cylinder closed. 3.
Service manual Balance refrigerant of the 2-way, 3-way valves Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve’s service port. § Leave the valve on the charge set closed. §...
Service manual Evacuation Procedure: 1. Connect the vacuum pump to the charge set’s centre hose. 2. Evacuation for approximately one hour. § Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less]. 3.
Service manual Gas charging Procedure: 1. Connect the charge hose to the charging cylinder. § Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. 2. Purge the air from the charge hose. §...
Service manual 12. Troubleshooting 12.1 Display board § Operation The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation. § Timer indicator: The indicator illuminates then TIMER is set ON. § PRE-DEF. indicator (For cooling & heating mode only) The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating.
Service manual 12.2 Troubleshooting For cooling mode: Operation Timer Failure phenomenon lamp lamp ☆ Indoor fan speed has been out of control for over 1 minute ☆ Indoor room temp. or evaporator sensor is open circuit or short circuit ☆ Over current protection of the compressor occurs 4 times ☆...
Service manual 12.4 Resetting phenomenon often occurs during operation. (That is automatically entering to the status when power is on.) The reason is that the instantaneous voltage of main chip is less than 4.5V. Check according to the following procedure: Resetting phenomenon often occurs during operation.
Service manual 12.7 Operation lamp off and Timer lamp flashes 12.8 Operation lamp on and Timer lamp flashes EEROM error, indoor PCB is defective. 12.9 Operation lamp flashes, Timer lamp flashes . This is alarm signal when the main chip can’t detect over-zero signal. When such failure occurs, the main control board must have fault.