Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1 Manual page 323

Midea air conditioner service manual
Table of Contents

Advertisement

Evaporator
Temp. up
Evaporator
down
8.10
Dehumidifying mode
8.7.6
The 4-way valve is off in dehumidifying mode
8.7.7
Compressor and Indoor Fan actions in dehumidifying mode
Indoor Fan
LOW
BREEZE
8.7.8
Low room temperature protection:
When room temperature decreases to below 10 , compressor and outdoor fan will
stop(indoor fan is Breeze). Dehumidifying operation will be resumed when room
temperature restores to over 13 .
8.7.9
At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the
same as that of cooling mode.
8.7.10
At dehumidifying mode, the action of fans of indoor is the same as that of air-only
mode.
T> TE6
T< TE6
>5 Minutes
T> TE5
Temp.
T< TE5
>5 Minutes
Compressor and Outdoor Fan
ON 5minutes
OFF 5minutes
On
Off
On
Off
Repeat on and off cycle.
On
Off
On
Off