Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1 Manual page 324

Midea air conditioner service manual
Table of Contents

Advertisement

8.11
Heating mode
8.8.6
Generally, the 4-way valve is open in heating mode, but it is closed in defrosting
mode.
8.8.7
Generally, the outdoor fan is turned off with the on-off action of compressor in heating
mode, except for the defrosting mode or the end of defrost.
8.8.8
Action of compressor and outdoor fan motor at heating mode:
Room temp. up
Room temp. down
8.8.9
Indoor Fan actions at heating mode
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but
Anti-cold wind function prevails.
Anti-cold wind control function at heating mode
Indoor exchanger temp. up
Indoor exchanger temp. down
8.8.10
Auto wind at heating mode
Room temp. up
Room temp. down
8.8.7
Indoor evaporator high-temperature protection at heating mode
Indoor exchanger temp. up
Indoor exchanger temp. down
Condition
Compressor
T> Ts+3
T<Ts+3
T< Ts+2
T>Ts+2
Condition
T= Indoor exchanger temp.
T<TE1
TE1<T<TE2
T>TE2
T> TE3
TE3<T<TE4
T<TE4
Condition
T=Indoor Temp.-Setting Temp.
T<2
T>2
T> 0
T<0
Condition
T= Indoor exchanger temp.
T<TE8
TE8<T<TE7
T>TE7
T>TE9
T<TE9
Outdoor fan
Off
Off
On
On
On
On
Off
Off
Indoor fan speed
Indoor fan speed
Compressor
On
On
Off
Off
On
Off
Breeze
Setting fan speed
Setting fan speed
Breeze
Off
High
Med.
Med.
High
Outdoor fan
On
Off
Off
Off
On