10.8.4 Rated capacity test
Set mode to cooling mode
Set temp. to 30 °C
Set fan speed to high speed
Push turbo button 5 times in 10 seconds.
Using special remoter controller
After 5 hours, cancel rated capacity test
10.9 Outdoor low temperature protection (optional)
Factory standard unit has not this function.
Unit stops when outdoor temp. is low than -15°C and lasting time more than 60 minutes, and unit runs
again when outdoor temp. more than -12°C.
10.10.
Automatic operation mode
The air conditioner automatically selects one of the following operation modes: cooling, heating or fan
only according to the temp. difference between room temp. (TA) and set temp. (TS).
TA—TS
TA—TS>2¡ æ
-1 ≤TA
¡ æ
-TS≤+2¡ æ
TA-TS<-1¡ æ
10.11.
Manual switch
10.11.1 Mode changes when push this button .
Cooing mode
10.11.2. At Cooing mode, after 30 minutes cooling operation whose fan speed is set as low, the A/C operates
with a setting temp. of 24¡ æ .
10.11.3. At auto mode, the A/C operates with a set temp. of 24¡ æ
10.12.
Timer Function
10.12.1. The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes.
10.12.2. Timer on: first turn off the A/C, the A/C will be automatically on at the set time.
10.12.3. Timer off: first turn on the A/C, the A/C will be automatically off at the set time
10.12.4. Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be automatically on
at set time, and later be off at the set time, then unit turns on at set time.
10.12.5. Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be automatically off
at set time, and later be on at the set time, then unit turns off at set time.
10.13.
Sleep mode
10.13.1 It is available at cooling, heating or auto mode.
10.13.2 Cooling:
The set temperature rise 1¡ æ
constant and the fan speed is kept at low speed.
10.13.3 Heating:
The set temperature decrease 1¡ æ
Operation mode
Cooling
Fan-only
Heating (air-only for cooling only type)
Auto mode Unit off
per hour. Two hours later, the set temperature will maintain as a
per hour. Two hours later, the set temperature will maintain as a
Cooing mode