Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1 Manual page 268

Midea air conditioner service manual
Table of Contents

Advertisement

8.10 Automatic operation mode
When running in automatic mode, the air conditioner automatically selects one of the
following operation modes: cooling, heating or fan only according to the temp. difference
between room temp. (TA) and set temp. (TS).
TA TS
TA TS>2
-1
TA TS +2
TA TS<-1
at auto mode, the indoor fan blows automatically in selected mode.
8.11 Forced cooling function
A: Select forced cooling function with the forced cooling button or the switch.
B: The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan
mode is set as low, the A/C operates at DRY mode with a set temp. of 24 .
C: All protections of remote control cooling are available at forced cooling operation.
8.12 Forced Auto function
A: Select forced auto function with the forced auto button or the switch.
B: In forced auto status the A/C operates at remote control mode with a set temp. of 24 .
8.13 Timer Function
8.14 Economic Running
Cooling: The set temperature rise 1
maintain as a constant and the air circulation is kept at low speed.
Heating: The set temperature decrease 1
temperature will maintain as a constant and the air circulation is kept at low speed (Cold air
proof function takes priority over all).
Auto: The economic running function operates in accordance with the selected running
mode by the auto mode.
Operation mode
Cooling
Fan-only
Heating (air-only for cooling only type)
per hour. Two hours later, the set temperature will
per hour. Two hours later, the set
26