66
ESP Serial Hub Installer/User Guide
The heartbeat rate is 10 seconds and the heartbeat time-out is 80 seconds.
All other values (transmit drain, no flush, send modem status, send comms status, no purge and
open persist) assume their default values.
Updates (modifies) the driver information for the ESP-4 MI hub at address 10.0.0.117.
Physical port 3 is remapped to logical port COM100 and physical port 4 is remapped to logical
port 110.
The transmit drain feature is disabled for port 1.
// The following command removes information about the ESP hub
// at IP address 10.0.0.116
remove=10.0.0.116
// The following commands provide driver installation information
// about the ESP hub at IP address 10.0.0.115
esp
type = esp-2 mi
ip = 10.0.0.115
mac = 00-80-7d-94-54-00
p1 = com30
p2 = com40
i1 = rs-485
i2 = rs-232
rate = 10
timeout = 80
end
//The following commands update driver information for the ESP-4 MI
//serial hub at IP address 10.0.0.117.
esp
type=esp-4 mi
address=10.0.0.117
p3=com100
p4=com110
f1=txdrain off
end