Chapter 3: Connection Methods, Attributes And Configurable Features; Serial Port Connection Methods - Avocent ESP Serial Hub Installer/User Manual

Esp serial hub
Table of Contents

Advertisement

CHAPTER
3
This chapter describes:
Connection methods, which are configured for each serial port
Attributes, which are configured for each serial port
Configurable features, which are enabled/disabled for the entire hub

Serial Port Connection Methods

There are several methods to access a serial port on an ESP hub.
Telnet server - see page 16
Raw TCP server - see page 17
Raw TCP client - see page 19
Modem emulation - see page 21
Configuration utility - see page 28
You may configure port connection methods using any of the available tools.
Exclusivity and restrictions
Each connection method may be enabled or disabled for each ESP port. A port may have multiple
connection methods enabled, with the following exceptions.
The raw TCP client connection method is exclusive; when it is enabled on a port, no other con-
nection methods can be enabled for that port. (Conversely, if other connection methods are
enabled for a port, you cannot enable the raw TCP client connection method on that port until
you disable the other methods.)
If you enable the raw TCP server connection method and enable the idle TCP buffering option
on a port, then the TCP server connection method becomes exclusive; no other connection
methods can be enabled for that port.