Operators Manual
ALS 321/421

2.2 Operator panel

The operator panel of the 321/421 is shown in Figure 2, it has 4 digit LED and 6 membrane
keys.
Figure 2 Operator panel
The six membrane keys have the following functions:
FEED:
By pressing this key one label will be dispensed. An error or warning indi-
cation may be cleared with this key. Additionally, each time the FEED key
is pressed the machine measures the distance to the next leading label
edge and stores this measurement as the label pitch.
CONTRAST:
With this key the contrast value of the label sensor can be adjusted to the
label material in use.
SPEED UP /
With these keys the labelling speed can be adjusted
DOWN
POSITION
These keys enable the adjustment of the start delay function, i.e. the posi-
tion of the applied label