Product Sensor - Avery Dennison ALS 321 User Manual

Table of Contents

Advertisement

Operators Manual
ALS 321/421
4.2.1

Product sensor

The product sensor starts the labelling. The source of the signal could be a optical sensor, a
switch or a signal from a PLC. The time between start signal and start of dispensing (adjusted
with POS) should be as small as possible. This means that an optical sensor should be placed
10 to 20 mm before the dispensing edge. The minimum distance is necessary for the internal
speed compensation.
The machine is supplied as standard with one socket for connecting the product sensor. You
may either use a NPN or PNP type sensor output.
NPN-Sensor
brown
Supply
white
Signal+
black
Signal-
blue
GND
S5-5-C8-30
Figure 14 Example for connecting an NPN sensor (Datalogic)
PNP-Sensor
brown
Supply
white
Signal+
black
Signal-
blue
GND
S5-5-C8-30
Figure 15 Example for connecting an PNP sensor (Datalogic)
Release 2/08
5
5
9
9
4
4
8
8
3
3
7
7
2
2
6
6
1
1
5
5
9
9
4
4
8
8
3
3
7
7
2
2
6
6
1
1
Page 24
+24V
red
27
white
34
blue
26
black
13
GND
CN33
+24V
red
27
white
34
blue
26
black
13
GND
CN33
Connections

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents