Friedrich 920-087-09 (12/10) Installation And Operation Manual page 15

Packaged terminal air conditioners & heat pumps
Table of Contents

Advertisement

Figure 15
TRIM HARNESS
TO LENGTH
3. Route. the. cut. ends. of. harness. through. the. conduit. connector.
assembly.and.flex.conduit.sleeve...Be.sure.to.use.the.supplied.
conduit. bushing. to. prevent. damage. to. the. cord. by. the. conduit..
.
The. cord. should. pass. through. the. Locknut,. Spacer,. Chassis.
Junction. Box,. Conduit. Connector,. Bushing,. then. the. Conduit.
Sleeve...See.Figure.17.
4. Route.the.cut.ends.of.the.power.cord.through.the.elbow.connector.
at.the.other.end.of.the.conduit...Tighten.screws.on.elbow.connector.
to.secure.conduit.sleeve.
5. Fasten.and.secure.the.elbow.connector.to.the.wall.junction.box.
cover.with.locknut...Place.and.mount.the.wall.junction.box.with.
the.four.wall.mounting.screws.making.sure.to.pass.the.wall.lines.
through.the.junction.box...Connect.and.join.all.wall.lines.with.the.
stripped.ends.using.wire.nuts...Tighten.both.screws.of.the.wall.
junction.box.cover.to.junction.box.
6. Follow.steps.4-6.on.page.19.and.refer.to.Figure.27.
TO CHASSIS JUNCTION
4.0 IN.
18.0 IN.
EXPOSE
WIRES
(1.0 IN.)
STRIP WIRE ENDS (0.5 IN.)
TO WALL JUNCTION
FRP032
Figure 16
WALL CONNECTION
GROUND
WIRE
HARNESS
JUNCTION
BOX COVER
Figure 17
LEADING SIDE FOR
WIRE HARNESS INSERTION
SPACER
SPACER
BUSHING
CONDUIT
SLEEVE
EXITING SIDE FOR
WIRE HARNESS
STRAIGHT
CONNECTOR
JUNCTION
BOX
GROUND
SCREW
COVER
SCREWS
FRP033
LOCKNUT
CHASSIS
JUNCTION
BOX
CONDUIT
CONNECTOR
FRP034
15