Patton electronics IM2RC/IA User Manual page 8

Ethernet bridge module
Table of Contents

Advertisement

Status Blinks yellow from one to eleven times to indicate system
status. Each pulse pattern is separated by a 2 second "off"
period. Greater pulse patterns have higher priority (buffer sat
uration has greater priority than an empty MAC table). Valid
system statuses are:
1 pulse = system status ok
2 pulses = No MAC entries in the MAC address table
3 pulses = Clear to send (CTS) or Carrier Detect (DCD) from
base unit are not asserted
4 pulses = IMRC2/IA buffer is saturated
5 pulses = WAN receive frame(s) too large
6 pulses = WAN receive frame(s) not Octet aligned
7 pulses = WAN receive frame(s) aborted
8 pulses = Detected WAN receive frame(s) with bad CRC
9 pulses = Detected LAN receive frame(s) too large
10 pulses = Detected LAN receive frame(s) not Octet aligned
11 pulses = Detected LAN receive frame(s) with bad CRC
After a status code is displayed eight times and the associat-
ed condition is removed, the status code will no longer
appear.
Link
Glows green to indicate good link integrity on the 10Base-T
twisted pair line.
13
PATTON ELECTRONICS MODEL IM2RC/IA
SPECIFICATIONS
LAN Connection:
RJ-45, 10Base-T, 802.3 Ethernet
Line Connection
RJ-45, female connector or terminal
block
MAC Address Table Size:
4096 entries
MAC Address Aging:
MAC addresses deleted after 8 min
utes inactivity
On-board Memory:
512 KB RAM; 128 KB FLASH
Frame Latency:
1 frame
Interface:
Card-edge connection to Patton
modems
LED Indicators:
(1) general status; (1) link integrity
Power Consumption:
250mA @ 5VDC, supplied
by front card modem
Temperature Range:
32 to 122ºF (0 to 50º C)
Dimensions:
2.04" x 3.24" (5.2 mm x 8.26 mm)
Compliance:
FCC part 15 Class A, CE marked per
EEC Directive 89/336/EEC, and Low
Voltage directive 73/23/EEC