Surface Mounting - Viking E-50-BK Technical Practice

Compact entry phones with color video camera
Table of Contents

Advertisement

C. Surface Mounting
A Viking model VE-3x5 can be used to surface mount an E-50 to a wall or post. Recommended mounting height to bot-
tom of VE-3x5 is 50" - 54". Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or
caulking. Route wire into the VE-3x5 box, securely screw it to wall or post and seal hole in box around wire with putty
or caulking. Note: Conduit may also be used when surface mounting wire, but should not enter through the top of the
VE-3x5. When routing wiring from above, a drip loop is required. WARNING: Do NOT use a typical "wet location box"
as not all styles seal properly with the E-50 faceplate.
D. Mounting the Faceplate
After the Rough-In box or VE-3x5 is securely mounted, caulking between the box and rough opening is completed (if
required), wires are connected, and camera is tilted and rotated to the desired position (as shown in section G). Remove
paper liner from face plate gasket, while firmly holding the LED light pipe in the faceplate, carefully slide the faceplate gas-
ket over the back of the light pipe and press gasket to the back of the faceplate. Push the 1-1/4" 6-32 screws through face-
plate holes and small holes in gasket, the faceplate gasket should retain the screws. Position the circuit board mounting plate
over screws. Align screws with single gang box bosses and tighten face plate until gasket is fully collapsed and the push but-
ton is protruding through the clearance hole in the face plate. Included 1/4" thick gasket will provide an adequate seal for
most siding surfaces; however for rough surfaces (ie: brick, stucco, etc.) additional caulking may be required.
1.8"
3.17"
Mounting Ears
4.92"
-OR-
Condensation
Drain Hole
Conduit Knockout
Optional VE-3x5 Surface Mount
Box with Black Satin Powder Paint
Finish (not included) WARNING: Do
NOT use a wet location box.
E. Wiring the E-50 Phone Board
(Ring
connector
included)
** Earth
Ground
(optional)
Green
Red
(Tip)
(Ring)
IMPORTANT: Electronic devices are susceptible to lightning and power station
!
electrical surges from both the AC outlet and the telephone line. It is recommended
that a surge protector be installed to protect against such surges.
* Note: The gel-filled (water-tight) butt connectors (3M Scotchlok UR2) are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of
0.082 inches. Do not strip wires prior to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled
ing screw to Earth Ground (grounding rod, water pipe, etc.) After fastening ring terminal to PCB mounting screw, bend terminal up to avoid interference with single
gang box.
*** Note:
Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking K-1900-5 Dialer (DOD# 317) or K-1900-30 Multi-Number Dialer (DOD# 300).
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking TBB-1B Talk Battery Booster may
be required, see DOD# 632.
4
Optional Wing
Brackets
(5) 3-Wire Gel-Filled
Optional
Butt Connectors
(included)
Wires from
Phone Board
2.00"
W/BL
Wide
Green
Min.
*2.25"
Blue
Red
2.84"
Deep
Tall Min.
Min.
Orange
CAT5E
Wires from
Cable
W/O
Red
Black
Green
W/G
Yellow
(4) Optional Dry
Wall Screws
(not included)
"Old Work" Rough-In Box
(Allied Molded 9331 box
shown, not included)
* CAUTION: Excessive wire length and/or using a
rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.
Back View of the
E-50 Circuit Board
Viking C-200 or C-250 Single Entry
Mounting Plate
Phone Controller (not included)
(see Applications section A, page 8)
VIKING
ELECTRONICS
* 3-Wire Gel-Filled
HUDSON, WI 54016
SINGLE ENTRY PHONE
Butt Connectors
CONTROLLER
(included) E-50
phone board is not
polarity sensitive
ON
1
2
3
-or-
Camera
Circuit Board
Mounting Plate
(included)
** Important: Push LED light pipe into faceplate hole, then place faceplate
upside down on a clean flat surface and push down on back side of plate
until light pipe is fully seated and straight. WARNING: Inserting the light pipe
more than one time can cause a loose fit.
Viking C-2000B 1-4 Entry Phone
Controller (not included)
(see Applications section B, page 8)
VIKING
©
MODEL C-200
©
VIKING
ELECTRONICS
VIKING
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7
8 9 10 11 12 13
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
J7-
J8-
1
2
3
1
2
3
LED1
LED2
LED3
C
LED4
C
C
EARTH
C.O. LINE
OUT TO
ENTRY
N.O. COM N.C.
GND
INPUT
PHONES
PHONE
AUX CONTACTS
(as shown above) and fasten a wire with ring terminal (included) from the mount-
3.125"
4.875"
1/4" Thick Foam
Facplate
Faceplate Gasket
(included)
(included)
*** Optional Viking
K-1900-5 Dialer or
K-1900-30 Multi-
Number Dialer
MODEL C-2000B
(not included)
VIKING
©
Programmable
Tone Dialer
MODEL: K-1900-5
Quick Programming Guide
1. Call the phone connected to the dialer.
2. Answer phone. Enter
& security code.
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
J9-
J10-
J11-
Viking Electronics, Inc.
1
2
3
1
2
3
1
2
3
Hudson, WI 54016
C
LED5
C
LED6
C
LED7
C
LINE IN
PHONE
To C.O. Line or
PABX/KSU station
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
** LED
Light Pipe
(included)
(2) 6-32 x 1.25" Long
5/64" Hexdrive Flathead
Screws (included)
**** C.O. Line or Analog
PABX/KSU Station
(programmed for ringdown)
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
VIKING
RINGDOWN
©
1
2
DLE-200B
RES
BUSY

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-50-bk-ewpE-50-bnE-50-bn-ewpE-50-pb-ewpE-50-pbE-50-ss ... Show all