Surface Mounting - Viking E-75-SS Technical Practice

E-75 series
Hide thumbs Also See for E-75-SS:
Table of Contents

Advertisement

C. Surface Mounting
A Viking model VE-5x5 can be used to surface mount an E-75 to a wall or post. Recommended mounting height to bot-
tom of VE-5x5 is 50" - 54". Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or
caulking. Route wire into the VE-5x5 box, securely screw it to wall or post and seal hole in box around wire with putty
or caulking. Note: Conduit may also be used when surface mounting wire, but should not enter through the top of the
VE-5x5. When routing wiring from above, a drip loop is required. WARNING: Do NOT use a typical "wet location box"
as not all styles seal properly with the E-75 faceplate.
D. Mounting the Faceplate
After the Rough-In box or VE-5x5 is securely mounted, caulking between the box and rough opening is completed (if
required), wires are connected, and camera is tilted and rotated to the desired position (as shown in section G).
Remove paper liner from face plate gasket and place it on back side of face plate aligning with push button hole. Push
the 1-1/4" 6-32 screws through faceplate holes and small holes in gasket, the faceplate gasket should retain the
screws. Position the circuit board mounting plate over screws. Align screws with double gang box bosses and tighten
face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate.
Included 1/4" thick gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick,
stucco, etc.) additional caulking may be required.
3.25"
5.22"
5.14"
3.63"
3.63"
(2) Junction Box to
2.25"
Double Gang Adapter
Plates and (4) 5/64 Hex
Optional VE-5x5 Surface Mount Box
Drive Flat Head Screws
with Black Satin Powder Paint Finish,
(included with the E-75)
not included (DOD# 424) WARNING:
Do NOT use a wet location box.
E. Wiring the E-75 Phone Board
(Ring
connector
VIKING
included)
** Earth
Ground
(optional)
Green
(Tip)
IMPORTANT: Electronic devices are susceptible to lightning and power station elec-
!
trical surges from both the AC outlet and the telephone line. It is recommended that
a surge protector be installed to protect against such surges.
* Note: The gel-filled (water-tight) butt connectors (3M Scotchlok UR2) are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of
0.082 inches. Do not strip wires prior to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled
ing screw to Earth Ground (grounding rod, water pipe, etc.) After fastening ring terminal to PCB mounting screw, bend terminal up to avoid interference with single
gang box.
*** Note: Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking K-1900-5 Dialer (DOD# 317) or K-1900-30 Multi-Number Dialer (DOD# 300).
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking TBB-1B Talk Battery Booster may
be required, see DOD# 632.
4
Wing Brackets
Belden
CAT5E
9537
Cable
Cable
*2.25"
-OR-
Deep
Min.
"Old Work" Double Gang Rough-In
Box with minimum dimensions of:
3.65"W x 2.84"H x 2.25"D. (Carlon BH234R box shown, not included)
* CAUTION: Excessive wire length and/or using a
rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.
Rear View of the
E-75 Circuit Board
Mounting Plate
* Gel-Filled
Butt Connectors
(included)
E-75 is not
polarity sensitive
Red
(Ring)
(9) 3-Wire Gel-Filled
Butt Connectors
(included)
Wires from
Phone Board
W/BL
Green
Blue
Red
Wires from
Orange
Camera
Red
W/O
Black
Green
W/G
Yellow
Wires from
Proximity Card
Black
Reader
Black
Red
Red
Green
Green
Circuit Board
White
White
Mounting Plate
(included)
** Important: Push LED light pipe into faceplate hole, then place face-
plate upside down on a clean flat surface and push down on back side
of plate until light pipe is fully seated and straight. WARNING: Inserting
the light pipe more than one time can cause a loose fit.
Viking C-200, C-250, C-500 or C-2000B
Entry Phone Controller (not included)
VIKING
MODEL C-2000B
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
8 9 10 11 12 13
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
J7-
J8-
J9-
J10-
J11-
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
LED1
LED2
LED3
C
LED4
C
LED5
C
LED6
C
LED7
C
C
C
-or-
(as shown above) and fasten a wire with ring terminal (included) from the mount-
1/4" Thick Foam
Faceplate Gasket
(included)
*** Optional Viking
K-1900-5 Dialer or
K-1900-30 Multi-
Number Dialer
(not included)
**** C.O. Line
or Analog
PABX/KSU Station
VIKING
©
Programmable
(programmed for
Tone Dialer
MODEL: K-1900-5
ringdown)
Quick Programming Guide
1. Call the phone connected to the dialer.
*
2. Answer phone. Enter
& security code.
(Factory set to 845464) Write your
VIKING
security code below:
DLE-200B
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
RES
Viking Electronics, Inc.
Hudson, WI 54016
LINE IN
PHONE
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
** LED
Light Pipe
(included)
(4) 6-32 x 1.25" Long
5/64" Hexdrive
Facplate
Flathead Screws
(included)
(included)
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
RINGDOWN
©
1
2
BUSY

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-75-bnE-75-pbE-75-whE-75-bk

Table of Contents