Note: This is a 1600A parts kit without chassis.
Shipping Weight: .45 kg (1 lb)
Connections:
Standard E-1600-50A/52A - RJ11, E-1600-50A-
EWP/52A-EWP - Gel-filled butt connectors
Speaker
(included)
Screen (included)
Speaker Gasket
(EWP only)
Connect to phone line
(E-1600-50A-EWP/52A-EWP)
(standard E-1600-50A/52A)
Connect to "INFO" button (E-1600-52A only,
requires a .75" diameter mounting hole)
Red call connected LED with
mounting hardware (requires a
.250" diameter mounting hole)
Connect to "PUSH FOR HELP" or "HELP" button
(requires a .75" diameter mounting hole).
Note: When using the included push button
switches, cut off forked portion of spade lugs and
fasten screws to barrel portion of spade lugs.
Important: If installing the EWP version outdoors, apply non-corrosive silicone (included with EWP version) to back side of LED and push button switches
after making all connections and testing. Completely encapsulate exposed switch connections (screw terminals/stripped wires) and bare wire connections.
E
-
1
6
0
0
-
5
5
E
-
1
6
0
0
-
5
5
The E-1600-55A is a universal emergency phone kit for installing behind elevator panels, or an installation requiring a custom panel. The finished panel
should provide: (4) studs (#6 diameter minimum) for mounting plate, audio holes for speaker and microphone, a momentary SPST push button switch and
a 0.25" diameter mounting hole for the LED. Alternatively, the LED can be cut off and the wires connected to a integral switch with LED (often found in
elevators). Note: An LED must be connected to the red and black wires for the phone to operate.
Optional Enhanced Weather Protection (EWP):
The optional EWP products feature sealed trim
pots, sealed DIP switches, hand soldered and sili-
con sealed connections, rubber boots and gaskets,
urethane potted circuit boards and gel-filled butt
connectors.
Need More Information on EWP?
?
Call (715) 386-4345 and select 859.
Shipping Weight: .73 kg (1.6 lb)
Connections: Telco - RJ-11 jack or wire
nuts, Switch - spade terminals
Material: 0.062" thick (16 gauge) zinc
plated steel
4.0"
Dust Cover -
Install prior to fastening
faceplate to finished panel.
Wire
Knockout
A
/
5
2
A
A
/
5
2
A
(
o
p
t
i
(
o
p
t
Side
View
0.827
2.37
2.60
Cone
2.10
Dia.
Mylar Speaker Dimensions
Connect to phone line
RJ11
Red (LED anode)
Black (LED cathode)
Clear Spacer Red Retaining
Lens
LED
Ring
A
A
(
o
p
t
i
o
n
a
l
E
(
o
p
t
i
o
n
a
l
E
Connect to
phone line
(EWP version)
Connect to
phone line
(standard
version)
Red "Call Connected" LED with
included mounting hardware
(requires a 0.25" diameter hole)
Clear Spacer Red 5mm Retaining
Lens
Connect to momentary push
2.1"
button switch with contact
rating of 50VDC/100mA min
*
Note: Additional wire length may be
added if required.
(4) Countersunk holes for
mounting the dust cover
(4) 0.25 diameter clearance holes
for mounting the unit to the back
side of a finished panel.
(4) 6-32 x 3/4" stainless steel flat head, hexdrive,
screws (included) for fastening dust cover
o
n
a
l
E
W
P
a
v
i
o
n
a
l
E
W
P
a
v
Optional Enhanced Weather Protection (EWP): The optional EWP products
feature sealed trim pots, sealed DIP switches, hand soldered and silicon
sealed connections, rubber boots and gaskets, urethane potted circuit boards
and gel-filled butt connectors.
(4) 0.335 x 0.177
mounting slots
for #4 or #6 studs
2.60
2.10
-or-
Black
Red
Gel-filled butt
connectors
(EWP only)
Red
-or-
Green
Red
EWP
Red
version
is hand
soldered
PUSH FOR
2.20
Black
HELP
VIKING
Black
2.40
BL-1 grade 2 black
braille label included
W
P
a
v
a
i
l
a
b
l
e
W
P
a
v
a
i
l
a
b
l
e
Gel-filled butt
connectors
(EWP only)
Red
-or-
Green
RJ11
Red (LED
anode)
*
Black (LED
cathode)
Round LED
Ring
*
Black
Black
1/16" thick foam gasket (included) for accoustically sealing
mic and speaker to back of finished panel. Remove backing
and adhere gasket to front panel of the E-1600-55A,
centering over speaker and microphone holes (as shown).
a
i
l
a
b
l
e
)
a
i
l
a
b
l
e
)
?
(2) 0.10 diameter
Call (715) 386-4345 and select 859.
mounting holes
Standard Mic Mounting Boot. Glue or
screw directly behind 0.04" - 0.125" diam-
.47
.785
eter hole in panel.
Note: Mic holes should be near the bot-
Mic Hole
tom of the boot to allow for drainage.
.50
EWP Mic Mounting Boot. Glue to the
back of your panel at an upward angle
1.0
(shown left) behind a 0.10" - 0.25" diame-
ter hole.
Panel
PC Board Mounting
3.54
3.20
These (2) mounting
holes are not available
on EWP models
©
(4) 0.156 diameter
mounting holes
)
)
4.50
2.0
Diameter
0.25
Diameter
5.0
Need More Information on EWP?
Side View
0.80
Maximum
0.17
0.5
1.50
2.95
0.95
Spade
Terminal
(included)
* Earth Ground
(optional)
2.25
0.25 Typ.
1.76
3.625
Typ.
5.0
3.77
4.50
(4) 0.25 diameter
holes (not used)
Stainless steel speaker and
microphone protection screens
5.