Installation on supports
Installation on a substructure, e.g. steel beam
Installation information:
■ Observe the max. load and distance
from the edge of the roof for the on-site
substructure in accordance with DIN
1055.
■ Install the on-site substructure at a
right angle and horizontally level to the
collector orientation.
■ Secure the connection brace onto the
retaining brackets between the sec-
ond and third, the fourth and fifth
collector supports, etc. (see diagram
below).
■ For every 1 to 6 collectors, secure two
cross braces diagonally side by side to
the adjustable supports (see diagram
below).
(cont.)
■ The side with the type plate must be
on the outside of the first and last col-
lector (see diagram on page 11).
Secure the pipework on only one col-
lector opposite the side with the type
plate.
■
!
Please note
Connection pipes should not
show any signs of damage.
Lubricate O-ring seals only
with the special valve grease
provided.
9