VIESMANN Service instructions for contractors Vitosol-F For applicability, see the last page VITOSOL-F Please keep safe. 5692 741 GB 6/2008...
Page 2
Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained & the Code of Practice of relevant trade associations, Danger & all current safety regulations as This symbol warns against the defined by DIN, EN, DVGW, TRGI, risk of injury.
Page 3
Instal- charge static loads. ling non-authorised compo- nents and non-approved modifications/conversion can compromise safety and may invalidate our warranty. For replacements, use only ori- ginal spare parts from Viessmann or those which are approved by Viessmann.
Index Index Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance ........Further details regarding the individual steps ..........Parts lists Parts list Vitosol 200-F, 300-F ..............12 Specification Vitosol 200-F, 300-F..................14 Solar-Divicon (accessory) ................14 Heat transfer medium (accessory)............... 14 Certificates Declaration of conformity ................
Commissioning, inspection, maintenance Steps - commissioning, inspection and maintenance For further information regarding the individual steps, see the page indicated Commissioning steps Inspection steps Maintenance steps Page • 1. Cleaning, testing for leaks and filling the solar heating system ............... •...
Commissioning, inspection, maintenance Further details regarding the individual steps Cleaning, testing for leaks and filling the solar heating sys- & Never drain the system with a 2. Close the shut-off valve of the fill vacuum pump. valve and open the drain valve. &...
Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Information & Heat transfer media containing gly- & After filling the system with the heat col can be damaged, if they are sub- transfer medium, ensure that the jected for long periods to system is properly vented and that temperatures above 170 °C (stag- heat is transferred inside the sys-...
Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Note The thermal insulation of external pipes must be resistant to tempera- ture and UV rays. The insulation must be protected against attack from small animals and birds (e.g. metal sheath), Checking the expansion vessel and the system pressure 1.
Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Ventilating the solar heating system 1. Open the air vent valve. 2. Set required flow rate above output Vent the circulation pumps. For rate of the circulation pump (see this, adjust the circulation pumps to following tables for approximate set their maximum speed switching the values).
Check the pH value with a pH strip in ture of the "Tyfocor LS " heat transfer the solar service case (accessory) medium with a Viessmann antifreeze (see page 14). tester or the manual refractometer in the solar service case (accessory).
Commissioning, inspection, maintenance Further details regarding the individual steps (cont.) Checking the switching function of the solar control unit Solar control unit installation and service instructions...
Parts lists Parts list Vitosol 200-F, 300-F When ordering spare parts: 013 Retaining screws Quote the part and serial no. (see 014 Profile clip type plate) and the item no. of the 015 Diagonal sealing strip required part (as per this parts list). 016 Support sleeve Obtain standard parts from your local 017 Resilient buffer...
Page 13
Parts lists Parts list Vitosol 200-F, 300-F (cont.)
Specification Vitosol 200-F, 300-F Type SV/SH Absorber area 2.32 4.76 Aperture area 2.33 4.96 Thermal capacity c kJ/(m ·K) 5.35 Max. idle temperature °C Permissible operating pressure Content, heat transfer medium litres 1.83/2.48 Solar-Divicon (accessory) Safety valve 6 bar, 120 °C Permissible oper- 6 bar Max.
Certificates Declaration of conformity We, Viessmann Werke GmbH & Co KG, D-35107 Allendorf, declare as sole responsible body, that the products Vitosol 200-F and 300-F conform to the following standards: DIN 1055 EN 12975 to Solar-KEYMARK In accordance with the following Directives, these products are designated _:...
Page 16
Vitosol 200-F, type SH2 Part no. 7248 238 Vitosol 300-F, type SV3 Part no. 7248 611 Vitosol 300-F, type SH3 Part no. 7248 612 Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB...