Viessmann Vitosol-F Installation Instructions For Contractors

Viessmann Vitosol-F Installation Instructions For Contractors

Flat-plate collector for pitched roofs above roof installation with roof hooks or mounting brackets

Advertisement

Quick Links

VIESMANN
Installation instructions
for contractors
Vitosol-F/-FM
Type SV and SH
Flat-plate collector for pitched roofs
Above roof installation with roof hooks or mounting brackets
VITOSOL-F/-FM
Dispose after installation.
5698338 GB/en 9/2017

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann Vitosol-F

  • Page 1 VIESMANN Installation instructions for contractors Vitosol-F/-FM Type SV and SH Flat-plate collector for pitched roofs Above roof installation with roof hooks or mounting brackets VITOSOL-F/-FM Dispose after installation. 5698338 GB/en 9/2017...
  • Page 2 Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Please note Note This symbol warns against the risk of material Details identified by the word "Note" contain additional losses and environmental pollution. information.
  • Page 3: Table Of Contents

    Index Information Disposal of packaging ................Symbols ....................Intended use ..................Preparing for installation Distribution of roof hooks or mounting brackets ........Type SV ....................■ Type SH ....................■ Installation sequence Fitting roof hooks ................... 11 Overview installation with roof hooks ..........11 –...
  • Page 4: Disposal Of Packaging

    Disposal of packaging Disposal of packaging DE: Use the disposal system organised by Viessmann. Please dispose of packaging waste in line with statu- AT: Use the ARA statutory disposal system (Altstoff tory regulations. Recycling Austria AG, licence number 5766). CH: Packaging waste is disposed of by the HVAC contractor.
  • Page 5: Intended Use

    Intended use The appliance is only intended to be installed and Any usage beyond this must be approved by the man- operated in sealed unvented systems that comply with ufacturer for the individual case. EN 12828 / DIN 1988, or solar thermal systems that comply with EN 12977, with due attention paid to the Incorrect usage or operation of the appliance (e.g.
  • Page 6: Distribution Of Roof Hooks Or Mounting Brackets

    Distribution of roof hooks or mounting brackets Type SV Standard snow loads For installations without roof hooks, mounting brackets are used in place of roof hooks. Fig. 1 1098 2175 3273 4350 5448 6525 8700 10875 1019 2038 3115 4192 5269 6346 8500...
  • Page 7 Distribution of roof hooks or mounting brackets (cont.) Higher snow loads Installation only with roof hooks. Fig. 2 Lower mounting rail 1098 2175 3273 4350 5448 6525 8700 10875 1972 3103 4180 5257 6334 8488 10642 g+h+g+h g+h+g+k g+h+g+k g+h+g+k g+h+g+k g+h+g+k g+h+g+k+g...
  • Page 8: Type Sh

    Distribution of roof hooks or mounting brackets (cont.) Type SH Standard snow loads For installations without roof hooks, mounting brackets are used in place of roof hooks. Fig. 3 2422 4844 7266 9688 12110 14532 19376 24220 2250 4500 6901 9302 11703 14104...
  • Page 9 Distribution of roof hooks or mounting brackets (cont.) Higher snow loads Installation only with roof hooks. Fig. 4 Lower mounting rail 2422 4844 7266 9688 12110 14532 19376 24220 2273 4674 7075 9476 11877 14278 19080 23882 300+h 300+h 300+h ·...
  • Page 10 Distribution of roof hooks or mounting brackets (cont.) Distribution of mounting plates Fig. 5 Lower mounting rail 78.5 99.5 120.5 2265 2268 2268 2268 2268 2268 2268 2268 2271 2271 2271 2271 2271 2271 — —...
  • Page 11: Fitting Roof Hooks

    Fitting roof hooks Overview installation with roof hooks – Fig. 6 Note Dimension x according to the width of the tile head. Roof hook Collector Mounting rail Timber, 38 x 58 mm (only for roof tiles) Timber, 30 x 100 mm (only for roof tiles) Type mm b...
  • Page 12: Fitting Roof Hooks For Tiled Roof Cover

    Fitting roof hooks (cont.) Fitting roof hooks for tiled roof cover Fig. 7 Timber ■ 38 x 58 x 2430/1570 mm ■ 30 x 100 x 2430/1570 mm Roof hook Zinc-plated countersunk chipboard screw (Spax-s) 6 x 80 mm Zinc-plated countersunk chipboard screw (Spax-s) 5 x 30 mm 30 x 100 38 x 58...
  • Page 13: Fitting Roof Hooks For Slate Roof Cover

    Fitting roof hooks (cont.) Fitting roof hooks for slate roof cover 1. Mark the position of the roof hooks. For dimen- sions, see page 11 and chapter "Distribution of roof hooks or mounting brackets" from page 6 2. Remove slates from the roof at the hook contact Fig.
  • Page 14: Fitting Roof Hooks For Plain Tiled Roof Cover

    Fitting roof hooks (cont.) Fitting roof hooks for plain tiled roof cover Fig. 13 Roof hook Zinc-plated countersunk chipboard screw (Spax-s) 5 x 30 mm 1. Mark the position of the roof hooks. For dimen- sions, see page 11 and chapter "Distribution of roof hooks or mounting brackets"...
  • Page 15: Fitting Mounting Brackets

    Fitting mounting brackets (for example on sheet steel roofs) Fig. 16 Mounting bracket Fig. 17 Installation of mounting brackets Collector Mounting rail Type mm b mm c 2380 1900 2100 2400 – ≥ 1056 1077 – ≥ Secure mounting brackets on site with a screw to the substructure.
  • Page 16: Fitting Mounting Rails

    Fitting mounting rails Fig. 19 For all types of roof Hexagon bolt M 8 x 10 Connecting part Mounting plate Mounting rail Clamping bracket Type SV: 1098 or 2175 mm ■ Tee slot bolt Type SH: 2422 mm ■ Hexagon nut M 8 Washer Turn tee slot bolts through 90°...
  • Page 17: Distribution Of Mounting Plates

    Fitting mounting rails (cont.) Distribution of mounting plates Fig. 21 Lower mounting rail 178.5 198.5 209.5 209.5 230.5 — — Installing collectors Component overview Fig. 22 Accessories for one collector array Locking ring fitting (90° elbow), 22 mm Connection pipe Support sleeve Connection set: Accessories for one solar thermal system...
  • Page 18 Installing collectors (cont.) Turn tee slot bolts through 90° for all installation steps. Fig. 23 Type plate Dim. r Number of collectors Type 31.5 31.5 52.5 31.5 52.5 73.5 94.5 115.5 The connection pipes must be free of any signs of On just one of the collectors, fit the pipework at the damage.
  • Page 19: Fitting The Connection Set And Collector Temperature Sensor

    Installing collectors (cont.) 3. Guide the connection pipes into the flow and return 6. Install additional collectors. connections. 7. Tighten all clamping brackets. 4. Hook in the next collector. 8. Fit the caps (part of the connection set). 5. Push the next collector carefully against the first and insert the connection pipes.
  • Page 20: Covering The Collector

    Fitting the connection set and collector… (cont.) Fig. 24 Flow connection Return connection Flared coupling Type plate 1. Insert the sealing plugs as far as they will go. 6. Insert the strain relief into the sensor well. Secure with profile clips. 7.
  • Page 21: Installation

    Soft solder could be weakened, particularly near the collectors, due to the high temperatures that occur there. Metal seal connections, locking ring fittings or Viessmann plug-in connections with double O-rings are the most suitable. If other seals such as flat gaskets are used, ade- quate glycol, pressure and temperature stability must be guaranteed by the manufacturer.
  • Page 22: Commissioning And Adjustment

    Non-return valves Expansion vessel Solar circuit pump Drip pan Air separator Collector Shut-off valve (adjusting screw above flow indica- DHW cylinder Cylinder temperature sensor Drain valve Collector temperature sensor Flow indicator Solar control unit Commissioning and adjustment "Vitosol-F/-FM" service instructions.
  • Page 24 Viessmann Werke GmbH & Co. KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040 E-mail: info-uk@viessmann.com...

This manual is also suitable for:

Vitosol-fmSvSh

Table of Contents