CIX40 Installation
Site Requirements
Site Requirements
This section defines the installation site requirements necessary to ensure a proper operating
environment for the CIX40. Also included are grounding requirements.
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 1.5 amps. The AC
outlet is recommended to be dedicated and unswitched. (See
Requirements" on page
A dedicated AC power circuit eliminates interference from branch circuit motor noise or the like,
and to prevent accidental power-off. To avoid accidental power turn-off, Toshiba recommends that
you do not use an On/Off wall switch on this dedicated AC circuit.
For the Strata CIX40, a reserve power source (HPFB-6) may be connected to the system to serve
as a power failure backup
Clearance and Location
The minimum clearance requirements for the
Strata CIX40 Base cabinet is shown in
Figure
1-3. Refer to
CIX40 cabinet mounting instructions.
Consider the following conditions when selecting
a location for the cabinet:
The location must be:
Dry and clean
•
Well ventilated
•
•
Well illuminated
Easily accessible
•
The location must not be:
•
Subject to extreme heat or cold
Subject to corrosive fumes, dust, or other
•
airborne contaminants
Subject to excessive vibration
•
Next to television, radio, office automation, or
•
high frequency equipment
If reserve battery power (HPFB-6) is to be
installed for the Strata CIX40, the batteries will
require a well-ventilated location close to the
CIX40 system cabinet.
1-8
1-10.)
(See Step 1 on page
Figure 1-7 on page 1-13
"AC Power and Grounding
1-43).
Top View
for
Front View
2"
12.5"
CIX40
Figure 1-3
CIX40 Cabinet Clearance
Requirements
Strata CIX40 R3 Installation & Maintenance
3.5"
Wall
36"
2"
2"
18"
2"
05/10