When connecting additional cards, connect the thin cable included on the "master" card to
the 3-pin plug CN 2. The other end replaces the second card's 5-pin connector. Make
sure to keep this (leftover) connector handy for later use.
Still more cards? No problem: Simply attach another cable from the CN 2 of the second
card to CN 1 of the third. And, last but not least, a cable from the CN 2 of the third, to the
CN 1 of the fourth (and last) PCI card.

The PHASE ControlPanel ...

The PHASE ControlPanel (or EWS ControlPanel of older models) will now automatically
configure the MasterClock settings, since the cards are now digitally synchronized. The
clock of the first (master) card is now set to "Internal". All additional cards (you can select
the models on the right-hand side of the ControlPanel with "Select Card#") are now set to
external synchronization.
All interfaces will now run using the sample frequency set on the master. If you would like
to also use an external clock for the first card (using a DAT recorder, for example), set its
master clock to "External" as well. The sync information are transmitted accordingly.
PHASE 28 (English)