TerraTec PHASE 28 Manual page 17

24 bit/192 khz multi i/o recording interface
Hide thumbs Also See for PHASE 28:
Table of Contents

Advertisement

1. Connection for the PHASE 28 cable adapter. Please ensure that the connector strip
is firmly screwed onto the PCI system, as the weight of the cable can otherwise cause
it to come unplugged.
2. Gain controller for analog input 1. Here, the present signal can be optimally
adjusted to the converter level. Any clipping is indicated by the corresponding LED (3).
3. Clipping LED for analog input 1. As soon as the signal reaches the clipping level (-
1dB @ 2.1 Volt RMS, 1kHz), the LED is lit. In this case, push back the gain with the
appropriate gain controller (2) until the LED stops blinking. If the setting range is not
sufficient to go below the clipping range, reduce the output level on your external
equipment (e.g. mixer).
4. Gain controller for analog input 2. Here, the present signal can be optimally
adjusted to the converter level. Any clipping is indicated by the respective LED (4).
5. Clipping LED for analog input 2. As soon as the signal reaches the clipping level (-
1dB @ 2.1 Volt RMS, 1kHz), the LED is lit. In this case, decrease the amplification
using the appropriate gain controller (4) just to the point where the LED stops blinking.
If the setting range is not sufficient to go below the clipping range, reduce the output
level on your external equipment (e.g. mixer).
®
6. EWS
Connect Sync-IN connection. For the internal synchronization of up to 4
EWS/PHASE PCI cards (5 contacts, the jumper must remain on the master card). For
more information, please read Chapter "Cascading and internal synchronization."
starting on Ü page 32.
®
7. EWS
Connect Sync-OUT connection. For the synchronization of up to 4
EWS/PHASE PCI systems (2 contacts).
PHASE 28 (English)
17

Advertisement

Table of Contents
loading

Table of Contents