FortiGate-5050 front panel

FortiGate-5050 front panel

FortiGate-5050 back panel

28
Figure 7
shows the front of a FortiGate-5050 chassis. Two FortiSwitch-5003 boards are
installed in slots 1 and 2. Three FortiGate-5001SX boards are installed in slots 3, 4, and 5.
The FortiGate-5050 primary Shelf Manager is also visible. The factory-installed shelf
managers provide power distribution, cooling, alarms, shelf status, and a telco alarm
interface for the FortiGate-5050 chassis.
Figure 7: FortiGate-5050 front panel with FortiGate-5001SX and FortiSwitch-5003 boards
installed
5
FortiGate-5001SX
boards
4
slots 3, 4,
and 5
3
2
FortiSwitch-5003
boards
1
slots 1 and 2
ShMC
2
Also visible on the front of the FortiGate-5050:
Electrostatic discharge (ESD) socket, used for connecting an ESD wrist or ankle band
when working with the chassis.
The location of the hot swappable FortiGate-5050 cooling fan tray behind panel.
Power LED.
Caution: Do not operate the FortiGate-5050 chassis with open slots on the front panel. For
optimum cooling performance and safety, the slots must contain a FortiGate-5000 series
board or an air baffle slot filler. As well the removable power supply panel must be installed
over the power connectors on the back of the chassis.
Figure 8
shows the back panel of a FortiGate-5050 chassis. The back panel includes two
redundant -48V to - 58V DC power input connectors labelled Input A and Input B. The
power input connectors provide redundant DC power connections for the FortiGate-5050
chassis and distribute DC power to the fan tray and the FortiGate-5000 series boards
installed in the FortiGate-5050 chassis. Each power input connector includes a 24 Amp
circuit breaker that also functions as an on/off switch for the power input connector.
If you require redundant power you should connect both power input connectors to DC
power. If redundant power is not required, you should connect power input connector A to
DC power. When operating, the power input connectors are covered with clear protection
plates.
USB
1
2
3
4
5
6
7
CONSOLE
PWR
ACC
USB
1
2
3
4
5
6
7
CONSOLE
PWR
ACC
USB
CONSOLE
1
2
3
4
5
6
7
ACC
PWR
Critical
Major
Minor
Alarm
Alarm
Reset
FortiGate-5050
Shelf Manager
FortiGate-5050 chassis
8
STA IPM
8
STA IPM
8
STA IPM
Hot-swappable
cooling fan tray
POWER
Power LED
ShMC
Hot Swap
Status
1
Console
Ethernet
ESD socket
FortiGate-5000 Series Introduction
01-30000-83466-20090108
http://docs.fortinet.com/
Feedback

Advertisement

Table of Contents
loading

Table of Contents