Fortigate-5140-R Chassis - Fortinet FortiGate-5000 Introduction Manual

Fortigate-5000 series
Hide thumbs Also See for FortiGate-5000:
Table of Contents

Advertisement

FortiGate-5140-R chassis

FortiGate-5140-R chassis
FortiGate-5000 Series Introduction
01-30000-83466-20090108
http://docs.fortinet.com/
Feedback
You can install up to 14 FortiGate-5000 series boards in the 14 front panel slots of the
FortiGate-5140 ATCA chassis. The FortiGate-5140 is a 12U chassis that contains two
redundant hot swappable DC power entry modules that connect to -48 VDC Data Center
DC power. The FortiGate-5140 chassis also includes three hot swappable cooling fan
trays and a front accessible air filter. If all 14 front panel slots contain FortiGate-5005A2,
FortiGate-5001SX, or FortiGate-5001FA2 boards the FortiGate-5140 chassis provides a
total of 112 FortiGate gigabit ethernet interfaces. If all 14 slots contain FortiGate-5001A
boards the FortiGate-5140 chassis supports 28 1-Gigabit ethernet FortiGate interfaces. If
you add FortiGate-ADM-XB2 modules to the FortiGate-5001A boards the FortiGate-5140
chassis supports another 28 10-Gigabit interfaces.
You can also install a FortiSwitch-5003A or FortiSwitch-5003 board in the FortiGate-5140
chassis to provide base backplane communications. Base backplane communications can
be used for HA heartbeat communications and for data communications. You can add a
second FortiSwitch-5003A or FortiSwitch-5003 board for redundancy. FortiSwitch-5003A
boards can also provide fabric backplane communication using the FortiGate-5140 fabric
backplane channels.
You can mix and match any combination of FortiGate-5000 series boards in the
FortiGate-5140 chassis. For example, you could install four FortiGate-5005FA2 boards,
four FortiGate-5001SX boards, and four FortiGate-5001FA2 boards. You can also install
FortiController-5208 and FortiGate-5005FA2 boards in a FortiGate-5140 chassis to create
a FortiGate-5005-DIST security system.
Some of the boards installed in a FortiGate-5140 chassis can be operating in a FortiGate
HA cluster and some can be operating as standalone FortiGate units. You can also
operate multiple HA clusters and standalone FortiGate units in a single FortiGate-5140
chassis. You can also use FortiSwitch-5003A or FortiSwitch-5003 boards to operate HA
clusters consisting of FortiGate-5000 series boards installed in multiple FortiGate-5000
chassis. You can also use FortiSwitch-5003A boards for fabric data communication
between chassis.
The FortiGate-5140 chassis requires -48VDC Data Center DC power. If DC power is not
available you can install a FortiGate-5053 power converter tray (purchased separately)
with FortiGate-5140 power supplies.
15

Advertisement

Table of Contents
loading

Table of Contents