Specifications

Electrical
Each icemaker and dispenser require a separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 115V, 60Hz, 1 phase.
Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each
Maximum icemaker amperage – 11 amps each
Cord and plug provided on icemaker and dispenser
Electrical connections
Model
25FB400A/W, 50FB400A/W, 110FB400A/W
25CT400A/W, 50CT400A/W, 110CT400A/W
25CR400A/W, 50CR400A/W, 110CR400A/W
VU155R400A/W, VU300R400A/W
VU155BR400A/W, VU300BR400A/W
VU155R400A/WX, VU155BR400A/WX
VU155NR400A/W, UD300R400A/W
VU155R800A/W, VU300R800A/W,
VU155R800A/WX,
VU155BR800A/W, VU300BR800A/W,
VU155R800A/WX
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
3/8" FPT condenser drain (water-cooled condenser only)
Notes: Slope to drain of 1/4" per foot (6mm per 30.4cm run) with a 1/2" min. is recommended.
Water shut-off recommended within 10 feet (3m), drain to be hard piped and insulated.
Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.
Follett recommends installation of an activated carbon filter in icemaker inlet water line.
Ambient
Air temperature
Water temperature
Water pressure
100˚ F/38˚ C max.
90˚F/32˚C max.
70 P.S.I max. (482 kPA)
Electrical connection
cord & plug provided
cord & plug provided
dispenser, icemaker
and bin signal:
cord & plug provided
dispenser, icemaker
and bin signal:
cord & plug provided
dispenser, icemaker
and bin signal:
cord & plug provided
50˚F/10˚C min. (best performance below 80˚F/27˚C)
40˚F/4˚C min. (best performance below 70˚F/21˚C)
10 P.S.I. min. (89 kPA)
5
Circuits required
115/60/1, 20 amp max. fuse size
115/60/1, 20 amp max. fuse size
115/60/1, (2) circuits required
dispenser: 15 amp max. fuse size
icemaker: 20 amp max. fuse size
115/60/1, (2) circuits required
dispenser: 15 amp max. fuse size
icemaker: 20 amp max. fuse size
115/60/1, (3) circuits required
dispenser: 15 amp max. fuse size
(2) icemakers: 20 amps max. fuse
size each