Technical specifications (all models)
Refrigeration system diagram
condenser
filter dryer
thermostatic
expansion
valve
Refrigeration pressure data
Notes: 1)
Water regulating valve is factory set at 225 PSIG head pressure.
2)
Readings within 10% of above table values should be considered normal.
Air-cooled Icemaker
Refrigeration Pressure
Discharge Pressure/Suction Pressure
Ambient air temperature ˚F/˚C
60/16
˚F/˚C
174/23
50/10
174/23
70/21
190/25
90/32
Compressor data
Compressor current draw
Air-cooled
Ambient air temp.
60˚F/15.6˚C
6.3A
Water-cooled
Water temp. at float
50˚F/10˚C
6.6A
Locked rotor amps
evaporator
high
pressure
vapor
80/27
100/38
psi
245/31
237/37
244/30
326/38
psi
psi
265/32
347/40
70˚F/21.1˚C
6.5A
60˚F/15.6˚C
6.7A
58.8
high pressure
high side
service port
switch
high
pressure
pressure
liquid
Water-cooled Icemaker
Refrigeration Pressure
Discharge Pressure/Suction Pressure
Condenser inlet water temperature ˚F/˚C
˚F/˚C
50/10
70/21
90/32
80˚F/26.7˚C
90˚F/32.2˚C
6.7A
70˚F/21.1˚C
80˚F/26.7˚C
6.7A
19
low side
service port
compressor
low
low
pressure
vapor
liquid
50/10
70/21
90/32
236/28
235/29
250/34
237/28
230/30
250/34
236/28
235/30
250/34
100˚F/37.8˚C
6.9A
7.1A
90˚F/32.2˚C
6.8A
6.9A
psi
psi
psi