Specifications; Evaporator Unit; Condensing Unit - Follett Horizon Elite HCF1010R/N User Manual

Table of Contents

Advertisement

§ Installation and service must be performed in accordance with all federal, state and local laws. It is the
responsibility of the technician to ensure that these requirements are met.
§ Warranty does not cover exterior or outside installations.
§ Moving parts. Do not operate with front cover removed.
§ Hot parts. Do not operate with cover removed.
§ To reduce risk of shock, disconnect power before servicing.
§ Drain line must not be vented.
§ Water supply must have particle filtration.
§ Most ice machine cleaners contain citric or phosphoric acid, which can cause skin irritation. Read caution label
on product and follow instructions carefully.
§ Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
§ Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.

Specifications

Electrical
Separate circuit and equipment ground required.

Evaporator unit

Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 5A

Condensing unit

1010 Single-Phase (Tecumseh AJA7490ZXDPN)
1010 Single-Phase (Tecumseh ASFR9510ZNAMC1)
1410 Single-Phase (Tecumseh AWA9513ZXDPN)
1410 Single-Phase (Tecumseh ASFS9516ZNAMC1)
1010 3-Phase (Tecumseh AWA9490ZXTPN)
1010 3-Phase (Tecumseh ASFR9511ZFAMC1)
1410 3-Phase (Larkin AWA9517ZXTPN)
1410 3-Phase (Larkin LZT015M6CFIM)
Plumbing
This equipment to be installed with adequate backflow protection to comply with applicable federal, state, and
local codes.
Notes:
§ Water supply must have particle filtration. Follett recommends the filter system that has integral scale inhibitors.
(Follett item# 00130286).
§ Follett does not recommend the use of water softeners or bowl scale inhibitors.
§ The potable water total dissolved solids (TDS) content must be greater than 10 ppm for the water control
system to function properly. If using reverse osmosis water filtration system, ensure TDS level is greater than
10 ppm.
2
CAUTION
Electrical
208-230 V, 60 Hz
WARNING
Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
Min Circuit
Max Circuit HVACR
Ampacity
breaker size
10.7A
10.7A
19.3A
16.4A
9.9A
9.9A
15A
15A
15A
15A
30A
25A
15A
15A
15A
20A