Refrigeration pressure data
§ Water regulating valve is factory set at 300 ±10 PSIG (2068.4 ± 69 kPA) head pressure.
§ Readings within 10% of table values should be considered normal.
Compressor data
Air-cooled
Ambient air temperature
Amperage
High-side pressure (psi)
Low-side pressure (psi)
Water-cooled
Condenser water
temperature
Amperage
High-side pressure (psi)
Low-side pressure (psi)
Locked rotor amps
Condenser water usage:
Gearmotor data
Gearmotor current
Locked rotor amps
14
MC_425A/W, MM_425A/W, MF_425A/W, _P425A/W Ice Machines
high side
service port
evaporator
high
pressure
vapor
60 F/15.6 C
70 F/21.1 C
220 V
230 V
220 V
2.65
2.25
2.77
219
199
256
28
29
30
60 F/15.6 C
70 F/21.1 C
220 V
230 V
220 V
2.8
2.4
2.9
290
290
291
31
32
31
220 V: 19.6A
@70 F/70F: 0.26 gal/min
220 V/60 Hz
1.0A (nominal)
6.8A
high pressure
switch
compressor
high
low
pressure
pressure
liquid
liquid
80 F/26.7 C
230 V
220 V
230 V
2.36
2.89
2.46
233
293
266
31
33
33
80 F/26.7 C
230 V
220 V
230 V
2.5
2.9
2.5
291
292
292
32
32
33
230 V: 18.2A
@90 F/70F: 0.56 gal/min
230 V/50 Hz
1.3A (nominal)
6.8A
low side
service port
low
pressure
vapor
90 F/32.2 C
100 F/37.8 C
220 V
230 V
220 V
3.01
2.57
3.13
330
306
367
35
36
38
90 F/32.2 C
100 F/37.8 C
220 V
230 V
220 V
2.9
2.5
3.0
292
293
293
32
34
33
230 V
2.68
346
38
230 V
2.6
294
34