Zibro S1523 Operating Manual

Zibro S1523 Operating Manual

Pvg international b.v.

Advertisement

S1523 - S1526 - S1534
S1550 - S1564
4
OPERATING MANUAL
2
KULLANIM KILAVUZU
20
TR

Advertisement

Table of Contents
loading

Summary of Contents for Zibro S1523

  • Page 1 S1523 - S1526 - S1534 S1550 - S1564 OPERATING MANUAL KULLANIM KILAVUZU...
  • Page 2 Dear Sir, Madam, Congratulations on the purchase of your Zibro airconditioner. You have acquired a high quality product that, if used responsibly, will give you many years of pleasure. Please read these instructions for use first in order to ensure the maximum life span of your airconditioner.
  • Page 3: Table Of Contents

    CONTENTS Safety instructions Parts and functions Before operation Instructions for use Air filter Maintenance Trouble shooting Guarantee conditions Technical data...
  • Page 4: Safety Instructions

    • Have any repairs and/or maintenance only carried out by a recognised service engineer or your recognised Zibro supplier. Follow the instructions for use and maintenance as indicated in the user manual of this device. • Always remove the plug of the unit from the wall socket when it is not in use.
  • Page 5: Bparts And Functions

    Do not install in the following places: • Heat or steam is generated in the vicinity. • Under influence by the atmosphere containing in excess salt (in coastal area), sulphide gas (in spa), ammonia, steam of high temperature and vapor. •...
  • Page 6 Air Inlet grill Mold-proof Air Filters * two on each side Remote *** The air flow direction can be Horizontal Vertical Air outlet Signal adjusted with the vertical and louver*** louver*** Receiver horizontal louvers. Beeping sound assures successfull signal transmission between wire- less remote and the indoor unit.
  • Page 7: Remote Control

    Remote Control TRANSMITTER FAN SPEED BUTTON Sends signals to the receiver of the indoor Use to adjust the fan speed. The indication unit. of the fa speed varies among “L” (Low), “M” (Medium), “H” (High), and “AUTO” FAN SPEED each time the button is pressed. INDICATION OPERATION MODE Indicates the fan speed selected by the fan...
  • Page 8: Cbefore Operation

    7 meters. 2. Attaching filters COMMENT • Never use the airconditioner without the air filter. • Only use suitable Zibro filters. This will prevent damage to your airconditioner. • Suitable filter packages are available at your dealer.
  • Page 9: Instructions For Use

    How to attach the air clean filters a. Open the front panel by pulling upward b. Remove the outer air filters. Push up the center tab of each filter slightly until it is released from the stopper, and remove the filter downward. Air filters CAUTION Do not touch the metalic parts to avoid injury, when attaching filters.
  • Page 10 Circulating Operation What is Circulating Operation? When you use other heating equipment, warmed air accumulates in the upper space of the room. When the room temperature reaches the temperature set by the remote controller, the indoor unit starts air circulating operation automatical- ly to equalize temperature differences between the upper and lower spaces of the room and consequently improves the heating efficiency.
  • Page 11: Heating Operation

    NOTE! • Even if you press the ON button right after the operation stop, the air conditioner will not start operation for approx. 3 min. in order to protect the compressor. The operation will start automatically after 3 min. of waiting. •...
  • Page 12: Automatic Operation

    Automatic operation In automatic operation the air conditioner selects the operation mode (cooling, dry, heating) according to the room temperature when it starts. • The air conditioner will restart in the previous mode if auto- How to select operating mode matic operation is resumed within 3 hours from the switch- Heating Cooling...
  • Page 13: Air Flow Adjustment

    Air flow adjustment Vertical adjustment During Cooling, Dry The vertical louver will move automatically to the suitable position when During Circulating, Operation Dry Operation ON/OFF button is pressed. level Approx. 10 level Swing of air flow degrees Approx. 60 degrees (70) The vertical louver will keep moving within the range illustrated on the level left, if the vertical louver button is pressed once.
  • Page 14 Programming the “ON Time” Press the “TIME ADJ” 2 times. Adjust the time with the button. The time setting changes in 10-minu- te intervals. Hold the button to fast forward the time. Press the “TIME ADJ” button two times. The setting of “ON Time” is com- plete and the present time appears.
  • Page 15 Press the “ON/OFF” button. Proceed from Step 5 (below) if the unit has been operated or the ON Timer has been set. Press the timer fixing button “ON”. The “ON Time” is displayed for 2 seconds and then the present time appears.
  • Page 16: Eair Filter

    Operation Designated Temperature Timer mode Air flow mode temperature Above 23°C Cooling 26°C Continuous Automatic Below 23°C Heating 23°C Continuous Automatic NOTE Emergency operation at the temperature between above 23°C and below 26°C just switch the machine in operation in “cooling mode” without actually “cooling”. It is not possible to operate in “Dry”...
  • Page 17: Fmaintenance

    MAINTENANCE WARNING! Before maintenance, be sure to turn off the system and the circuit breaker. Remote controller Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth. Indoor body Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water.
  • Page 18: Trouble Shooting

    TROUBLE SHOOTING CAUTION! In the event of a malfunction (burning smell, etc.) immediately stop operation, disconnect the Power Supply plug and consult sales shop. Before requesting service, perform the following checks: Problem Cause / Solution The system does not start re-operation This is for protection of the system.
  • Page 19: Guarantee Conditions

    Damage caused by not using suitable Zibro filters is not covered by the guarantee. Refrigerant loss and/or leakage because of incompetent (dis)connecting the units is not covered by the guarantee conditions applicable to this product.
  • Page 20: Technical Data

    TECHNICAL DATA Model S 1523 S 1526 S 1534 S 1550 S 1564 Type air-conditioner Wall mounted split Wall mounted split Wall mounted split Wall mounted split Wall mounted split Cooling capacity (max) * 2300 2600 3400 5000 6400 Cooling capacity (max) * btu/h 7850 8870...