  • Page 2 Dear Sir, Madam, Congratulations on the purchase of your Zibro airconditioner. You have acquired a high quality product that, if used responsibly, will give you many years of pleasure. Please read these instructions for use first in order to ensure the maximum life span of your airconditioner.
  • Page 3: Table Of Contents

    CONTENTS SAFETY INSTRUCTIONS PARTS NAMES OPERATING TEMPERATURE MANUAL OPERATION OPERATION WITH REMOTE CONTROL OPTIMAL OPERATION ADJUSTING AIR FLOW DIRECTION HOW THE AIR CONDITIONER WORKS MAINTENANCE OPERATION TIPS TROUBLESHOOTING TIPS GUARANTEE CONDITIONS TECHNICAL DATA READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air con- ditioner properly.
  • Page 4: A Safety Instructions

    • Have any repairs and/or maintenance only carried out by a recognised service engineer or your recognised Zibro supplier. Follow the instructions for use and maintenance as indicated in the user manual of this device. • Always remove the plug of the unit from the wall socket when it is not in use.
  • Page 5: B. Parts Names

    • It is advised to stay out of the direct airstream. • Never drink the drain water from the airconditioner. ATTENTION! • Never use the device with a damaged power cord, plug, cabinet or control panel. • Failing to follow the instructions may lead to nullification of the guarantee on this device.
  • Page 6: Operating Temperature

    FUNCTION INDICATORS ON INDOOR UNIT DISPLAY PANEL Signal receptor AUTO indicator This indicator illuminates when the air conditioner is in AUTO operation. DEFROST indicator (For Cooling & Heating models only) This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.
  • Page 7: Manual Operation

    MANUAL OPERATION The air conditioner can be operated manually on the air conditioner itself as well as with the remote con- trol included. For operation with the remote control please refer to chapter E “Operation with Remote Control”. When operating without the remote control the air conditioner will only work in the AUTO-mode. For operation without the remote control follow these instructions: Panel Manual control...
  • Page 8: Operation With Remote Control

    OPERATION WITH REMOTE CONTROL NOTE! • Always aim the remote controller towards the receiver on the indoor unit and make sure there are no obstacles in between the remote control and the receiver on the indoor unit. Otherwise the remote control signal will not be picked up by the receiver and the air conditioner will not work properly.
  • Page 9 Timer on Button: Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minutes increments. When the setting time displays 10Hr, each press will incre- ase the auto-timed setting 60 minutes increments. To cancel the auto-timed program, continue pressing the button until nothing displays.
  • Page 10: Automatic Operation

    Operating the Remote Controller Install / Replace Batteries Use two dry alkaline batteries (AAA/LR03). Do not use rechargeable batteries. Remove the battery cover on the back of the Remote Control by pulling it according to the arrow direction shown on the cover. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
  • Page 11: Dry Operation

    NOTE! The FAN ONLY mode cannot be used to control the temperature. In this mode, only steps 1, 3 and 4 are applicable. DRY Operation 1. Push the Mode button to select DRY. 2. Push the button ( ) to set the desired temperature from 21 C to 28 C. 3.
  • Page 12: Optimal Operation

    3.4 Push the Timer off button again to set the time you want to stop the operation. 3.5 After setting the TIMER, there will be half a second delay before the remote controller transmits the signal to the Air Conditioner. NOTE! •...
  • Page 13: Adjusting Air Flow Direction

    ADJUSTING AIR FLOW DIRECTION • Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. • Adjust the horizontal louver using button on the remote controller. • Adjust the vertical louver manually. Adjusting the horizontal Air Flow Direction (up - down) The air conditioner automatically adjusts the horizontal air flow direction in accor- dance with the operating mode.
  • Page 14: How The Air Conditioner Works

    CAUTION • The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set). • Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode.
  • Page 15: Maintenance

    MAINTENANCE WARNING It is necessary to stop the air conditioner and disconnect the power House- hold supply before cleaning. Drain Cleaner Cleaning the indoor unit and remote controller Thinner CAUTION • Use a dry cloth to wipe the indoor unit and remote controller. •...
  • Page 16: Checks Before Operation

    Maintenance If you plan to idle the unit for a long time, perform the following: Operate the fan for about 6 hours to dry the inside of the unit. Stop the air conditioner and disconnect power. Remove the batteries from the remote controller. The outdoor unit requires periodic maintenance and cleaning.
  • Page 17: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection • The compressor cannot restart for 3 minutes after it stops. Anti-cold air • The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 18: Troubleshooting Tips

    6. The air conditioner turns to FAN only mode from COOL or HEAT mode. • When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode to the set point.
  • Page 19 Problem Cause Solution Power cut Wait for power to be restored. Check that plug is securely in wall Unit may have become unplugged. receptacle. Replace fuse / reset relay / reset Fuse may have blown. circuitbraker Battery in Remote controller may have Unit does not start Replace the battery.
  • Page 20: Guarantee Conditions

    Damage caused by not using suitable Zibro filters is not covered by the guarantee. Refrigerant loss and/or leakage because of incompetent (dis)connecting the units is not covered by the guarantee conditions applicable to this product.
  • Page 21: Technical Data

    TECHNICAL DATA Model S 1026 S 1034 Type air-conditioner Wall mounted split Wall mounted split Cooling capacity (max) * 2600 3400 EE Class* EER* 3.02 3.02 Heating capacity (max) * 2800 3900 Heating performance COP* 3.25 3.42 Dehumidifying capacity ** L / 24h 28.8 Power consumption cooling...