Fluke DSP-100 User Manual page 25

Lan cablemeter/cable analyzer
Table of Contents

Advertisement

1. If you are using a DSP-100 main unit as the remote, turn the remote unit's
rotary switch to SMART REMOTE. If you are using a smart remote unit, turn
its rotary switch to ON.
2. Use a 2m patch cable of the correct impedance to connect the remote to the far
end of the cable link.
3. On Model DSP-100, remove any cable connected to the test tool's BNC
connector.
4. Turn the rotary switch on the main unit to AUTOTEST.
5. Verify that the settings displayed are correct. You can change these settings in
the SETUP mode.
6. Use a 2m patch cable of the correct impedance to connect the test tool to the
near end of the cable link. On Model DSP-2000, connect to the CABLE TEST
jack.
7. Press
to start the Autotest.
Getting Started
Autotest on Twisted Pair Cable
2
2-9