21. Power on the target domains.
XSCF> poweron -d domain_id
22. Confirm that the target domain has been correctly started.
XSCF> showlogs power
23. Confirm no abnormality occurred by using showlogs error -v and
showstatus(8) commands.
XSCF> showlogs error -v
XSCF> showstatus
If you encounter any hardware abnormality of the XSCF contact a service engineer.
Adding a New CMU Equipped with SPARC64 VII
to an Existing Domain Configured with SPARC64
VI
1. When the Solaris OS version is Solaris 10 8/07, upgrade it to Solaris 10 5/08 or
apply the mandatory patches described in
page
2. To use SPARC64 VII processors, apply the relevant patches to the software in use,
if necessary.
3. Log in to the XSCF on an account with platform administrative privileges.
4. Use the showstatus(8) command to confirm that a component in Faulted or
Deconfigured status doesn't exist.
XSCF> showstatus
If no failures found, the following message appears: "No failures found in
System Initialization." In case of other messages, contact a service engineer
before proceeding to the next step.
5. Turn off the power to a domain assigned the CMU of which you add the CPU.
XSCF> poweroff -d domain_id
6. Confirm that the target domain stopped.
XSCF> showlogs power
38
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008
2.
"Solaris OS Patch Information" on