JUKI AC-172NN-1790 Instruction Manual page 85

Table of Contents

Advertisement

No.
K14
Knife cylinder lowering time (Optional)
Y-feed motor origin compensation
K15
Needle-rocking motor origin compensa-
K16
tion
K17
Presser lifter motor origin compensation
Pattern selection function under sewing mode Inef-
K18
fective/effective
: Ineffective
Thread trimming on the way in continuous stitching
K19
Permitted/Prohibited
: Permitted
K20
Cloth cutting knife return power
Ths tem sets output power at the tme of
returnng the cloth cuttng knfe.
Release amount of bobbin thread trimmer
K21
at the start of sewing
Ths tem sets the amount of releasng the bob-
bn thread trmmer at the start of sewng.
Presser lifter speed
K22
Ths tem sets presser lfter speed.
Material edge detecting sensor setting
K23
: Material edge
sensor is dis-
abled 
Marking light setting
K24
: Marking light is
disabled 
K25
Auxiliary clamp setting
: Auxiliary clamp
is disabled 
Material edge detecting sensor positioning
K26
Adjust the dstance between the needle entry
pont and the locaton at whch the materal
edge detectng sensor detects the materal edge so that
the jump amount equals to the set value.
Needle thread trimming adjustment mode
K51
Needle thread trmmng adjustment moton
starts wth READY key ON.
K52
Bobbin thread trimming adjustment mode
Bobbn thread trmmng adjustment moton
starts wth READY key ON.
Sensor check mode
K53
Sensor check starts wth READY key ON.
"K53 Sensor check mode" p.82"
/ Refer to
Output check mode
K54
Output check starts wth READY key ON.
K55
Adjuster adjustment mode
Actvate the adjuster adjustment mode by
turnng ON the Ready key. Termnate the
mode by turnng ON the Reset swtch.
Item
: Effective
: Prohibited
: Material edge
sensor is en-
abled
 :  Marking light is
enabled
Auxiliary clamp
 :
is enabled
− 81 −
Setting range
Edit unit
5 to 300
5ms
–120 to 400
1 pulse
(0.025mm)
–10 to 10
1 pulse
(0.05mm)
–100 to 10
1 pulse
(0.05mm)
0 to 3
1
1 to 15
1 pulse
1 to 3
30.0 to 100.0
0.1 (0.1mm)
Initial value
50
0
0
0
Ineffectve
Permtted
0
8
2
Materal edge
sensor s ds-
abled
Laser
marker s
dsabled
Auxlary
clamp s
dsabled
65.0

Advertisement