!2
!3 B rown
!3
7
Degrease
!6
!2
!3 B lue
!3 B lack
!4
7)
Insert materal edge detectng sensor asm. cord
7 nto materal edge detectng sensor juncton
cord !3 .
8)
Degrease the top surface (at the locaton where
reflective sheet !6 is to be affixed) of feed plate
!5 .
9)
Affix reflective sheet !6 on feed plate !5 algnng
!5
wth the end face of the slot of the feed plate.
If the relevant part of the surface of feed
plate !5 is not adequately degreased,
reflective sheet !6 is likely to come un-
stuck.
– 12 –
4)
Secure materal edge detectng
sensor cord by means of cable clp
!2 together wth the hand-swtch
cord and the ar hose.
5)
Open the cover of the control box.
6)
Connect brown cord (contact) of
the materal edge detectng sensor
juncton cord !3 to sensor juncton
cord B asm. !4 (CN105-30), black
cord (contact) to sensor juncton
cord B asm. !4 (CN105-26) and
blue cord (contact) to sensor junc-
ton cord B asm. !4 (CN105-27),
respectvely.