Command Control - InFocus IN5100 series User Manual

Hide thumbs Also See for IN5100 series:
Table of Contents

Advertisement

Command Control

Serial Communication Configuration
Visit our website for additional RS-232 settings and information.
To control this projector via RS-232, connect a null modem cable and set the
control system serial port settings to match the following communication
configuration:
RS-232 Port Settings
Setting
Bits per second
Data bits
Parity
Stop bits
Flow control
Emulation
Network Communication Configuration
For network control, you can access the projector through Port 23 (Telnet).
We use the same control codes on serial as we do over the network. InFocus
network control uses the Telnet packet structure.
Command Format
All commands consist of 3 alpha characters followed by a request, all
enclosed in parentheses. The request can be a read request (indicated by a
"?") or a write request (indicated by 1 to 4 ASCII digits).
A read request example:
(AAA?) where
Value
19,200
8
None
1
None
VT100
(starts the command
AAA denotes the command
? denotes the read request
) ends the command
A read command returns the range and the current setting, for example:
Read Command Examples
Function
Command
Brightness
(BRT?)
Volume
(VOL?)
Lamp Hours
(LMP?)
A write request example:
(AAA####) where
(starts the command
AAA denotes the command
#### denotes the value to be written
(leading zeros not necessary)
) ends the command
Some commands have ranges, while others are absolute. If a number
greater than the maximum range is received, it is automatically set to the
maximum number for that function. If a command is received that is not
understood, a "?" is returned. With absolute settings, "0" is off, 1-9999 is on.
The one exception is the Power command, where 0 is off and 1 is on.
To assure the projector can process a command, wait 3 seconds before enter-
ing the next command.
42
Response
(96-160,128)
(0-32,16)
(0-32766, 42)