Managed Modules

To manage one or more iMcV-LIM(s), an SNMP agent must be present in the chassis.
To configure Managed Modules, install the module first, and then configure using the
management software.
All Fiber Type information is now loaded into the NVRAM during manufacturing.
This is viewed only via iView² software, within the modules details.
Requirements:
SNMP Firmware version C2
iView² 1.8.6 or higher
Management software overrides any hardware settings (e.g., jumper, switch, etc.); a
module must be configured so that it will be managed via the software. Until a module
installed in a managed chassis is configured via the software, the module (and its LEDs) may
not work properly.

Unmanaged Modules

Before installing, configure the iMcV-LIM modules for desired features. The table
below indicates the available features and settings for the iMcV-LIM modules.
After configuring the DIP Switches for the desired settings, install the module and
connect the appropriate cables (refer to the Installating an iMcV-LIM section for more
information).
NOTE
2