Managed Modules; Unmanaged Modules - IMC Networks iMcV-MediaLinX Operation Manual

Switching media converter
Hide thumbs Also See for iMcV-MediaLinX:
Table of Contents

Advertisement

Managed Modules

To manage one or more iMcV-MediaLinX Modules, an SNMP agent must be present
in the chassis: The iMediaChassis series requires an SNMP Management Module. To
configure Managed Modules, install the module first, and then configure using the
management software. All fiber type information is now loaded into a NVRAM
during manufacturing. This is viewed only via iView² software, within the modules
details.
Requirements:
SNMP Firmware version C2
iView² 1.8.6 or higher
If the module is going to be managed via the software management, configuration settings
will override any hardware settings, such as DIP Switches or jumpers.

Unmanaged Modules

Before installing, configure iMcV-MediaLinX Modules for desired features listed in the
table below. After configuring the DIP Switches for the desired settings, install the
module and connect the appropriate cables. For further information, refer to the
Installing an iMcV Module section.
DIP Switch on
S1
1
2
3
4
5
6
7
8
9
10
When possible, it is always a good idea to configure DIP Switches to match software settings.
NOTE
Feature
Auto Negotiation
TX FDX
TX 100Mbps
TX 10Mbps
TX LinkLoss
FX LinkLoss
FX FDX
FX HDX
FiberAlert
Selective Advertising
Far End Fault
Flow Control
BEST PRACTICES
2
DIP Switch Options
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
Default Setting
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF