Imcv-medialinx series 10/100/1000 mbps and standard and extended temperature (ie) 10/100 ethernet snmp-manageable, switching media converters (2 pages)
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe B prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. Product Version Description Class Class Dual AC iMediaChassis/20 Dual DC ACDC iMediaChassis/6 Dual AC Dual DC iMediaChassis/3 ACDC...
At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship.
Table of Contents FCC Radio Frequency Interference Statement ............ii Class A ........................ii Class B ........................ii Warranty....................... iii About the iMediaChassis/20 ...................1 iMediaChassis/20 Features ..................1 Alarm Reset, Last Gasp and Temperature Gauge ..........1 Alarm Reset Button ...................2 Last Gasp Alarm ....................2 Temperature Gauge ..................2...
SNMP Management Module. Power supply modules are user-replaceable and hot- swappable. iMediaChassis/20 Features The iMediaChassis/20 line offers models available in dual AC, dual DC and ACDC versions. It offers features such as end-user replaceable power supply modules, temperature monitoring, Last Gasp and an Alarm Reset Button.
• When the AC line fails Temperature Gauge The iMediaChassis/20 includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis temperature via SNMP. If the chassis’ temperature rises above the specified level, the SNMP agent sends a trap (configured in iView²) to the administrator.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the IMC Networks.
15A listed circuit breaker, etc.). DC Power Supply Module Wiring Instructions The following diagram shows the wiring configuration for a -48 VDC power supply module for the iMediaChassis/20-2DC and iMediaChassis/20-ACDC. NOTE The chassis is protected against incorrect wiring configurations. When wired incorrectly, the...
In order to manage an iMediaChassis series, the SNMP Management Module needs to be installed in the appropriate slot of the chassis. • Install the iMediaChassis/20 SNMP Management Module into the first slot of the chassis. NOTE This slot is ONLY for the Management Module; do not install Application Modules...
Replacing Power Supply Modules User-Replaceable Power Supply Modules While power supply modules are redundant *, failed power supply modules should promptly be replaced to maintain network integrity and prevent data loss. To replace a power supply module: Disconnect the power source from the power supply module. Remove the screws of the retainer plate (on some AC modules).
2 (PS2) AC Power Connector Redundant ACDC Power Supply, Close-Up NOTE For 850-10960-XX iMediaChassis/20, all models in that model number series can support Dual AC, Dual DC or ACDC. The power supply modules for that model number series are interchangeable.
Specifications Input Specifications Dual AC 100 to 240V AC, 50/60Hz, 3.5/1.5A Dual DC -48V DC, 5A ACDC 100 to 240V AC, 50/60HZ, 2A -48V DC, 4.4A Operating Temperature 0° C to 50° C (32° F to 122° F) Storage Temperature Dual AC &...
About the iMediaChassis/6 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/6 is 1U high, Rackmountable and supports optional redundant power supply modules, as well as an SNMP Management Module. iMediaChassis/6 Features The iMediaChassis/6 series offers a line of models including single AC, single DC, dual AC and dual DC.
Last Gasp Alarm The iMediaChassis series includes the Last Gasp trap feature, “Remote Chassis Down”, which sends a Trap when the following occurs: • Both power supply modules malfunction • Both power supply modules are powered down • When the AC line fails Temperature Gauge The iMediaChassis/6 includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis.
4. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the IMC Networks.
Page 18
5. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 6. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
User-Replaceable Power Supply Modules The iMediaChassis/6 ships from IMC Networks with one or two power supply modules installed depending on the model. Chassis ordered with one power supply come with a filler tray installed in the second slot.
Installing Applications Modules To install a module: Remove the blank bracket (if present) covering the slot where the module will be installed. IMC Networks recommends installing blank brackets in unused module slots. Slide the module into the chassis using the card guides.
iMediaChassis/6 Specifications Input Specifications 100 to 240V AC, 50/60Hz, 1A -48V DC, 2A Operating Temperature: -25° C to 50° C (-130° F - 122° F) -40° C to 100° C (-40° F - 212° F) Storage Temperature: -40° C to 85° C (-40° F - 185° F) -55°...
About the iMediaChassis/3 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/3 is a 1U high, Rackmountable, capable of offering redundant power supply modules, and supports an SNMP Management Module. iMediaChassis/3 Features The iMediaChassis/3 series offers a line of models including single AC, single DC, dual AC, dual DC and ACDC version.
If mounting on a Rackmount shelf, align holes of the chassis to the shelf and secure with screws. The Rackmount shelf is sold separately. To purchase the Rackmount shelf (part number (895-39949); visit the IMC Networks’ Product Accessories page: https://www.imcnetworks.com/Products/acc.cfm Rackmounting requires a Rackmount shelf for mounting up to two units side by side.
If mounting the chassis on a wall, place two #10 panhead screws (not supplied) on the wall according to the distance of the holes on the chassis, and then hang the unit on the screws. All versions are intended for use in a Restricted Access Location (RAL). A readily accessible disconnect device shall be incorporated in the building installation wiring.
The fans will activate and then they will turn off when the button is released. If the fans do not activate, contact IMC Networks. Fans are not end-user replaceable. The red Alarm Reset Button also functions as a Fan Test button. To verify fan functionality, hold the button down for several seconds, the fans should engage.
SNMP Write Lock The SNMP Write Lock switch is located on the back of the iMediaChassis/3. The SNMP Write Lock switch prevents a new management board from re-configuring the application module settings (e.g., the status of features such as LinkLoss, FiberAlert, Force mode, etc.) made via SNMP on any previous Management Modules.
Page 27
LNK/ACT Glows green when a link is established on port. Blinks green when data activity occurs. Glows yellow when port is in Full-Duplex mode. FDX/COL Blinks yellow when port is operating in Half- Duplex mode and collisions occur. Glows yellow when temperature of unit TEMP surpasses a user-defined level.
iMediaChassis/3 Specifications Input Specifications 100 to 240V AC, 50/60Hz, 0.75A 35V DC to 75V DC Max, 1.6A Operating Temperature 0° C to 50° C (32° F to 122° F) -40° C to 50° C (-67° F to 122° F) Storage Temperature -40°...
IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020 E-Mail: techsupport@imcnetworks.com Web: www.imcnetworks.com WARNING Disconnect all power supplies before servicing.
Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products Do not remove unit from its protective packaging until ready to install. Wear an ESD wrist grounding strap before handling any module or component.
Voltage Limits (2006/95/EC). Certified to Safety of Information Technology Equipment, Including Electrical Business Equipment. For further details, contact IMC Networks. European Directive 2002/96/EC (WEEE) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste.
Page 32
The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any errors that may appear in this document. iMediaChassis Series is a trademark of IMC Networks. Other brands or product names may be trademarks and are the property of their respective companies.
Need help?
Do you have a question about the iMediaChassis/20 and is the answer not in the manual?
Questions and answers