SNMP Management Module LEDs

The SNMP Management Module features several LEDs. The LED functions are:
LNK/ACT
Glows green when a link is established on port.
Blinks green when data activity occurs.
Glows yellow when port is in Full-Duplex mode.
FDX/COL
Blinks yellow when port is operating in Half-
Duplex mode and collisions occur.
TEMP
Glows yellow when temperature of unit
surpasses a user-defined level.
PS
Glows yellow when one power supply module
malfunctions.
FAN A / FAN B
Glows yellow when a fan malfunctions.

Installing the iMediaChassis 6

Install the chassis first before installing any modules into an iMediaChassis.
When installing the chassis, be sure to observe the following precautions to prevent
electrical or mechanical damage:
1.
Protect the chassis from exposure to sunlight and electrical or magnetic fields.
2.
Ensure that the equipment rack remains stable, even with the addition of the
chassis and its associated cabling.
To install a 6-slot Rackmount chassis:
1.
Have four #10 screws and four clip nuts available (hardware may vary
depending on rack type). The rest of the hardware is supplied with the unit.
2.
Locate a suitable location in the rack for installation and secure the clip-nuts
onto the mounting rails. Use screws to attach the chassis to the rack.
3.
Plug the chassis into a reliable, filtered power source.
4. Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideration should be
given to installing the equipment in an environment compatible with the
maximum ambient temperature (Tma) specified by the IMC Networks.