Genie GCL-GT Installation Manual page 42

Heavy duty operator trolley
Hide thumbs Also See for GCL-GT:
Table of Contents

Advertisement

Safe-T-Beam® Monitored Photocell Self-diagnostic Troubleshooting Chart
SOURCE ( RED LED )
SENSOR ( GREEN LED )
ON
OFF
OFF
2 BLINKS, PAUSE
(REPEAT)
2 BLINKS, PAUSE
(REPEAT)
3 BLINKS, PAUSE
(REPEAT)
4 BLINKS, PAUSE
(REPEAT)
WARNING
USING CONSTANT CONTACT ON THE CLOSE BUTTON
WILL OVERRIDE EXTERNAL REVERSING DEVICES,
INCLUDING PHOTOCELLS.
GCL-GT
Heavy Duty Operator
ON
NORMAL OPERATION
1. POWER HEAD NOT POWERED
OFF
2. WIRING FROM POWER HEAD BAD
1. WIRING TO SOURCE MISSING OR BAD
ON
2. POWER HAS BEEN INTERRUPTED
1. BEAM NOT ALIGNED
2. BEAM OBSTRUCTED
ON
3. SENSOR DEFECTIVE
1. WIRE TO SENSOR MISSING OR BAD
OFF
2. SENSOR DEFECTIVE
1. SENSOR RECEIVING INTERFERENCE 1. ATTEMPT TO DETERMINE SOURCE OF
ON
1. SOURCE NOT SENDING PULSES
ON
2. SOURCE DEFECTIVE
ACTUATING THE OPERATOR BY
:
www.geniecompany.com
INDICATED CONDITION
WARNING
RECOMMENDS THAT LINE VOLTAGE WIRING BE PERFORMED
BY A QUALIFIED ELECTRICIAN. SEE SECTION 5 FOR
ADDITIONAL WIRING INSTRUCTIONS.
REQUIRED ACTION
NONE REQUIRED
1. CHECK BREAKERS, FUSES, PLUGS
2. CHECK WIRING FOR OBVIOUS SHORTS
1. CHECK WIRING
2. REMOVE POWER AND REAPPLY
1. CHECK ALIGNMENT
2. CHECK FOR OBSTRUCTION
3. CALL CUSTOMER SERVICE
1. CHECK WIRING
2. CALL CUSTOMER SERVICE
INTERFERENCE
2. CALL CUSTOMER SERVICE
1. CALL CUSTOMER SERVICE
2. CALL CUSTOMER SERVICE