Specifications - Generac Power Systems GUARDIAN SERIES Overview

Standby generators - prepackaged 17 kw air-cooled gas engine generator sets guardian series
Hide thumbs Also See for GUARDIAN SERIES:

Advertisement

SPECIFICATIONS

GENERATOR
Rated Maximum Continuous Power Capacity (LP)
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current – 240 Volts
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)
Unit Weight
Dimensions (L" x W" x H")
Sound output in dB(A) at 23 ft. with generator operating at normal load
Sound output in dB(A) at 23 ft. with generator in Quiet-Test™ low speed exercise mode
ENGINE
Type of Engine
Number of Cylinders
Displacement
Cylinder Block
Valve Arrangement
Ignition System
Governor System
Compression Ratio
Starter
Oil Capacity Including Filter
Operating RPM
Fuel Consumption
Natural Gas
cu.ft./hr.
1/2 Load
Full Load
ft 3 /hr (gal/hr)
Liquid Propane
1/2 Load
Full Load
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
For Btu content, multiply ft
3
/hr x 2520 (LP) or ft
CONTROLS
2-Line Plain Text LCD Display
Mode Switch
-Auto
-Off
-Manual/Test (start)
Programmable start delay between 10-30 seconds
Engine Start Sequence
Engine Warm-up
Engine Cool-Down
Starter Lock-out
Smart Battery Charger
Automatic Voltage Regulation with Over and Under Voltage Protection
Automatic Low Oil Pressure Shutdown
Overspeed Shutdown
High Temperature Shutdown
Overcrank Protection
Safety Fuse
Failure to Transfer Protection
Low Battery Protection
50 Event Run Log
Future Set Capable Exerciser
Incorrect Wiring Protection
Internal Fault Protection
Common External Fault Capability
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power
decreases about 3.5 percent for each 1,000 feet above sea level. Sound output ratings from certain points on the generator subject to change based on installation parameters.
3
/hr x 1000 (NG)
Model 005873-1 (17 kW)
17,000 Watts*
16,000 Watts*
70.8 LP/66.6 NG
Less than 5%
65 Amp
Group 26R 12 Volts and 525 Cold-cranking Amperes Minimum
455/210.9
48 x 25 x 29 (1218 x 638 x 732)
Model 005873-1 (17 kW)
GENERAC OHVI V-TWIN
992cc
Aluminum w/Cast Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
12 Vdc
Approx. 1.9 Qts./1.8L
59 (1.61) [6.09]
94 (2.57) [9.73]
Simple user interface for ease of operation.
Automatic Start on Utility failure. 7 day exerciser.
Stops unit. Power is removed. Control and charger still operate.
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Standard
Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration).
5 seconds
1 minute
Starter cannot re-engage until 5 sec. after engine has stopped.
Standard
Standard
Standard
Standard, 72Hz
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
240
1
2
60Hz
1
66
60
2
9.5:1
3,600
183
261
®