Section 2: General Information Specifications - Generac Power Systems PWRcell X7602 Owner's Manual

Hide thumbs Also See for PWRcell X7602:
Table of Contents

Advertisement

Section 2: General Information
Specifications
Description
Max. cont. grid-tied AC power @ 122º F (50º C)
Max. cont. islanded AC power without an external
1
transfer switch
Max. cont. islanded AC power w/ external transfer
switch and single 6 module battery cabinet
Max. cont. islanded AC power w/ external transfer
switch and 2 battery cabinets (8 modules minimum)
Peak motor starting current (2 sec)
Normal output frequency AC
Grid Voltage Line to Neutral (L-N)
Grid Voltage Line to Line (L-L)
Peak efficiency
Allowable split phase imbalance
CEC weighted efficiency
AC terminals wire size
DC terminals wire size
STOP terminals wire size
Weight
Thermal management
Weatherization rating
Enclosure Material
Description
REbus voltage
REbus current
REbus Input short circuit current
REbus Input source backfeed current to input source
Output power factor rating AC
Operating voltage range AC, X7602 Series (L-N)
Operating voltage range AC, X7602 Series (L-L)
Operating voltage range AC, X11402 Series (L-N)
Operating output voltage range AC, X11402 Series (L-L)
Continuous output current AC islanded
PCS controlled current grid-tied
Continuous output current AC grid-tied
Output fault current duration
Full Power operating ambient temperature range
Utility interconnection voltage and frequency
trip limits and trip times
Trip voltage and frequency limits
Trip voltage accuracy
Trip time accuracy
1
When islanded, continuous power output is restricted to 7.68kW unless backup power is routed through an external transfer
switch.
2
Peak performance, values provided for 104º F (40º C)
3
Rating for one DC input. Four total.
4
Includes ambient temperature rising from inverter operation.
* In Island mode XVT11402 Protected loads only supply 2 phases 120 VAC L-N, 208 L-L which results in lower power than in
grid tied 3 phase mode. The low value of the range is for full L-L loading while high value of the range is full L-N loading.
Inverter limits its REbus current to adhere to its AC power rating. Total REbus current capability from multiple REbus
sources may safely exceed this value as the inverter safely limits the amount utilized.
Owner's Manual for Generac PWRcell Inverter
Units
kW
kW
kW
2
kW
2
A rms
Hz
VAC
VAC
%
%
%
AWG
AWG
AWG
lb (kg)
3
1
4
X7602
7.6
7.6
9.0
11.0
240
97.3
96.5
-
-
-
Units
Min
V
360
A
A
A
-
V rms
106
V rms
212
V rms
106
V rms
184
A rms
A rms
A rms
A / ms
°F (°C)
-4 (-20)
See Voltage and Frequency Trip Thresholds in the PWRcell
Inverter Installation Manual for more information.
-
General Information
X11402
11.4
7.6
9.0
Range 9.6 to 11.0*
50
60
120
208
97.7
Up to 30%
97.5
14 to 6
18 to 6
30 to 14
70.9 (32.1)
forced convection
NEMA Type 3R
powder-coated steel
Nominal
380
120
240
120
208
50 / 2000
+122 (+50)
2% +/-2 cycles
Max
420
30
30
30
1
132
264
132
228
32
32
42
3