Assembly Of Backguard/High Shelf; Code Requirements; Electrical Supply; Single And Three Phase Connection - Garland S680 SERIES Installation And Service Manual

Restaurant ranges and salamanders
Table of Contents

Advertisement

INSTALLATION continued
3 . Remove the terminal block access cover .
4 . Pass the wires though cable entrance hole .
5 . Secure the cable connector
6 . Terminate the salamander wire at the terminal block
provided (Red to L1, Black to L2 or N, Green to GRN or E) .
NOTE: When mounting a salamander over an existing range
in the field, an independent fussed connection must be
made though the knock out plate provided in the main back
of the salamander .

Assembly of Backguard/High Shelf

The back guard or high shelf will have been shipped
separately . To install, put the backguard/high shelf on the
rear of the range, slipping the uprights into the opening on
each burner box side . Fasten the upright to the burner box
side with four hex fasteners provided .

Code Requirements

The Garland S/SS680 series complies with the standards CSA
C22 .2 no .109 – latest edition, the UL197 – latest edition and
the NSF#4 – latest edition . The installation and connection
of this appliance must comply with current codes . In Canada
– The Canadian Electrical Code Part 1 and in the USA – The
National Electrical Code .
The Garland SU680 series complies with the essential
requirements of the Directives 73/23/EEC, 89/336/EEC,
89/392/EEC, 93/68/EEC and the standards, EN60335,
IEC801 .2, IEC801 .3, IEC801 .4, IEC801 .5, IEC801 .6 and
IEC801 .11 .

Electrical Supply

Before attempting the electrical connection, the rating plate
should be checked to ensure that the equipment's electrical
characteristics and supply electrical characteristics agree . On
ranges and salamanders the supply entrance is located at the
rear or alternatively on the main bottom . The supply terminal
block is accessible from the front . The electrical supply must
be adequate for the voltage, phase, and current marked on
the rating plate .
Page 10
NOTE: A means of disconnection from the supply having
a contact separation of at least 3 mm in all poles must be
incorporated in the fixed wiring .
This equipment is intended to be installed with fixed
permanent wiring .
WARNING: This appliance must be grounded .

Single And Three Phase Connection

Unless otherwise noted, all ranges are shipped from the
factory for three phase connection . Salamanders are shipped
from the factory for single phase connection . A wiring
diagram is attached to the rear of each appliance . Visually
check all electrical connections . The range is wired at the
factory as specified on the order . If it is necessary to change
the phasing refer to the wiring diagram .

Commissioning

Ensure all circuit breakers located in the lower compartment
are set to the ON (1) position .
1 . Ensure that all controls are in the OFF position and turn
on the main electrical supply .
2 . Operate each section of the range or salamander in
accordance with the instructions given in the Use's
Manual .
3 . Check that the product functions correctly and that the
voltage supply to the unit does not drop more than 5%
when all sections are operated simultaneously .
When the operation has been checked, hand the OPERATING
INSTRUCTIONS to the User or purchaser for retention and
instruct them in the efficient and safe operation of the
appliance .
Part # P152 Rev 1 (01/13/10)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents