Replacing The Power Supply Unit - Fujitsu PRIMERGY BX400 S1 Operating Manual

Blade server
Hide thumbs Also See for PRIMERGY BX400 S1:
Table of Contents

Advertisement

Hot-plug components
8.4.1

Replacing the power supply unit

If a power supply unit fails, an error message is output on the LocalView display.
The defective power supply unit can be replaced during operation.
V
CAUTION!
CAUTION! The power supply unit can be very hot!
Ê Check the power supply unit LEDs on the back of the system unit (see
figure 16 on page
Ê First unplug the power cable of the defective power supply unit from the
mains.
Ê Unplug the power cable from the insulated socket of the defective power
supply unit.
Figure 46: Open release lever
Ê Unlock the locking lever (1) and open the release lever (2).
134
68) to find out which unit is defective.
Operating Manual
BX400 S1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents